selection guide
3'
DIA
.9m
1.2-1.5m
1
3/8" - 3/4"
AHB013
AHB013
(9.53mm-19.05mm)
1
1" - 1 1/2"
AHB013
AHB013
(25.4mm-38.1mm)
This product has been designed, manufactured and instructions written for the sole use of preventing water pipes from freezing. Improper installa-
tion, use and/or maintenance of electrical heating cable can cause fire, electric shock and/or freezing of pipe.
This safety alert symbol indicates important safety messages in this manual. when you see this symbol,
be alert to the possibility of personal injury and carefully read the message that follows.
Warning: Use on water pipes only and comply with these important instructions. Minimum pipe length is 3 feet.
precautions
1.
If after reading the following instructions, you still have questions regarding installation or operation of this heating cable, call toll-
free (800) 562-6587 for assistance. M – F, 8:00 AM – 5:00 PM EST.
2.
Heating cables must be installed in compliance with all National, State, Provincial and Local Codes.
Check with your local electrical inspector for specific details.
3.
These instructions must be saved and made available to the owner and transferred to future owners.
Before starting, be sure you have selected the correct length heating cable for the pipe to be protected, see Selection Guide.
selection guide
Choosing the right length of pipe freeze protection cable:
Cable should be long enough to run along bottom of horizontal
pipes and weather side of vertical pipes (including valves) without
crossing or spiraling. Never use a cable longer than the pipe it is
intended to protect.
1. Refer to the Selection Guide for proper cable selection.
Installation Instructions
4-5'
6'
7-8'
9'
1.8m
2.1-2.4m
2.7m
1
1
1
1
AHB016
AHB016
AHB019
2*
1
2*
1
(1)AHB013
AHB016
(1)AHB016
AHB019
Length of Pipe
12'
13-14'
15'
16-17'
3.7m
4-4.3m
4.6m
4.9-5.2m
1
1
1
1
AHB112
AHB112
AHB115
AHB115
1
1
2*
2*
(1)AHB016
AHB112
AHB019
(1)AHB019
AHB115
*When using 2 cables, overlap cables with overrun zone on opposite sides of pipe.
2. Cable will be applied straight along pipe, and will protect
pipes up to 1-1/2 inches in diameter.
3. For pipe lengths other than standard heating cable sizes, use two
heating cables in parallel on opposite sides of the pipe (see
illustration). Maximum "overrun" should not exceed 3 feet.
Do not install on pipe shorter than 3 feet.
18'
19-20'
21-23'
24'
5.5m
5.8-6.11m
6.4-7m
7.3m
1
1
2*
1
AHB118
AHB112
AHB124
AHB118
1
2*
1
2*
(1)AHB019
(1)AHB115
AHB118
AHB124
(1)AHB112
AHB112
(1)AHB112
25-27'
28-29'
30'
7.6-8.2m
8.5-8.8m
9.1m
1
2*
1
AHB124
AHB115
AHB130
2*
1
2*
AHB115
AHB130
1