Setting The Parameters; Parameters Description - Kübler 901 Manual De Instrucciones

Contador electrónico de preselección
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Page 4 | ENG
during this countdown, the device switches back
to the previous operating mode. If the keys are
released after 0 is reached, parameter setting is
activated and the first parameter is displayed.

4.2 Setting the parameters

The key of the 1st decade allows switching
among the available parameters (e.g. add-sub)
and the key of the 6th decade allows switching
over to the following function. The duration of the
fugitive pulse is set using the keys of decades
1-3. After the last input (dP), the key of the 6th
decade allows jumping back to the start of the
programming routine; pressing simultaneously
the reset key and the keys of the 5th and 6th
decades allows saving the parameters.
Note: Every time the programming routine is
called up, the counter switches back to the
basic parameter setting, i. e. the previous pro-
gramming is lost and the counter and preset
values are reset to zero.

4.3 Parameters description

(see also the function sequence)
Funct.Count: Pulse preset counter operating
mode
Funct.Time: Time preset counter operating
mode
tMode:
Programmable time range (only
for Funct.Time), SEC=seconds,
Min=minutes, hour=hours
Count Add: Adding counting mode
Count Sub: Subtracting counting mode
LooP off:
Automatic repetition off
When parameter LooP is „off" and
dELAY time is 0.0, the output is
activated when the preset value
is reached and remains activated
until reset is performed.
LooP on:
Automatic repetition on
When parameter „LooP is „on", the
counter is reset automatically and
the output emits a fugitive pulse
for the time of the duration set in
dELAY.
rELAY no:
Normally open contact
rELAY nc:
Normally closed contact
dELAY:
Output signal duration: fugitive
signal programmable from 0.01

Publicidad

Tabla de contenido
loading

Tabla de contenido