Troubleshooting - NSS Aero Plus Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SYMPTOM
Reduced Air Flow.
Excessive Vibration.
Rubbing Sound.
Will Not Turn On.
Slow Starting Or Will Not Start.
Motor Stops From Over Heating.
*
* NOTE: This motor is thermally protected and will turn OFF if overheated – it will restart automatically when cool.
NOTE: Unplug machine before servicing – Caution – moving fan.
Repair service for this machine must be performed by an NSS authorized service center. Repairs performed by an
unauthorized company will void the machine warranty. If you require assistance finding an authorized service center,
contact NSS Enterprises.
OPERATION MANUAL
AERO PLUS

TROUBLESHOOTING

CAUSE
Restriction.
Impeller Out Of Balance.
Impeller Bent And Hitting Housing.
Bad Switch.
Low Voltage.
Restriction.
SOLUTION
Check Inlets And Exhaust For
Obstructions. Remove Any That Are
Found.
Replace Impeller.
Replace Impeller.
Replace.
Eliminate Extension Cords, Or Other
Appliances Being Used On Same Circuit.
Remove Any Restrictions.

Publicidad

Tabla de contenido
loading

Tabla de contenido