Maintenance And Cleaning; Product Specifications - BriskHeat IBC Tote Manual De Instrucciones

Calentador de tanques de 1500 vatios controlado digitalmente
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
The following chart shows how to adjust all the operating parameters.
Unit will automatically exit this menu 5 seconds after last button press.
‐ 
‐ 
val-
The operating menu is available when the terminal control box is set ON (ON) mode.
To change the setpoint, press
or
‐ 
display. Then use
or
buttons to adjust.
‐ 
To change control hysteresis, hold down
the
left side of the display. Then use
or
‐ 
be set from 2-20°F (1 to 10°C).
Controller will exit these menus automatically 5 seconds after the last button press. The descrip-
tion of the parameters is explained below:

MAINTENANCE AND CLEANING

Because this unit is immersed directly into whatever liquid is to be heated, deposits may form onto the heating elements.
When these are typical mineral deposits from water, BriskHeat recommends vinegar or a commercial Calcium/Lime/Rust
cleaning solution.
If instead the heater was immersed in any other solution leaving residues, clean in accordance with that solution's
MSDS.
If scrubbing is required, use a nonmetallic scouring pad such as Scotch-Brite.
®
© BriskHeat
Corporation. All rights reserved
IBC/Tote Tank Immersion
‐ 
O
‐ 
‐ 
Setpoint
when the actual process value appears on the
for 3 seconds. Controller will show
buttons to adjust value. Control hysteresis can
.
7
Heater
WARNING

Conditions of maintenance and supervision ensure that only qualified persons
service the installed systems.

Fire and shock hazard - Damaged cables can cause electrical shock,
arcing, and fire. Do not attempt to repair or energize unit with damaged
cable.

Continued circuit operation is necessary for safe operation of equipment.

PRODUCT SPECIFICATIONS

Voltage Rating
Wattage
Flange Connection Type
Sensor Type
Immersion Length
Setpoint Range
Measurement Range
Ambient Temperature Range
Temperature Display
Heater Element Exterior
Ingress Protection Rating
symbol on
Accuracy
Alarm
Power Cord
120 VAC
240 VAC
Circuit Protection
IBC/Tote Tank Immersion
120 / 240 VAC
Integral NTC 10 kΩ
34" (86 cm) overall length, bottom
18" (46 cm) heated
41-167°F (5-75°C)
-49-383°F (-45-195°C)
41-122°F (5-50°C)
3 digit, °F
Incoloy 840
0.2°F (0.1°C)
Fixed high-limit 180°F (82°C)
10 ft (3 m)
NEMA 5-15P
Bare wire leads
Integrated 106°C thermal fuse
®
© BriskHeat
Corporation. All rights reserved
8
Heater
1500 W
2" NPS
IP54
.

Publicidad

Tabla de contenido
loading

Tabla de contenido