Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
Read these instructions carefully so as to familiarise yourself with the appliance before fiting the appliance to a gas cylinder.
1. General
• This is an economic gas appliance designed for an optimal cooking experience using environment friendly LP gas.
• The appliance conforms to BS EN 484: 2019 and SANS 1539:2017
• This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
• Note that figures in this user manual are shown for visual purposes only and may differ to your appliance.
• Please read all the instructions and warnings on the appliance before use.
It is important that all gas connections have been correctly connected to prevent any gas leaks.
Do not use a leaking, damaged or malfunctioning appliance.
This appliance requires a hose and regulator to operate.
Ensure that the appliance is used in a well-ventilated area.
• Handle the appliance with care, do not drop it.
• When using a pot, the minimum recommended pot size is 150mm and maximum pot size is 300mm.
• The gas cylinder is to be used in an upright position only.
• Read the instructions before using the appliance.
• For outdoor use only!

2. Safety information

These instructions are for your safety and to help you avoid risk of injury and/or damage. All
warranties will become void if you do not follow these instructions.
The hose and seal on the regulator must be checked for wear or damage before every use
and before connecting to the gas cylinder.
In the event of light back (where the flame burns back and ignites at the jet) immediately
turn off the gas supply by first closing the control valve onthe gas cylinder and then the
appliance valve. After the flame is extinguished remove the regulator and check the
condition of its seal, replace the seal if in doubt. Re-light the appliance. Should the flame
persistently light back again return the product to your authorised CADAC repair agent.
Ensure the appliance is used away from flammable materials. Minimum safe distances;
above the appliance 1.2 m, at the rear and sides 600mm.
Do not use an appliance that is leaking, damaged or which does not operate properly.
Ensure that the gas cylinder is fitted or changed in a well-ventilated location, preferably
outdoors, away from any sources of ignition, such as naked flames and away from other
people.
Keep gas cylinders away from heat and flame. Do not place on a stove or any other hot
surface.
Ensure that the assembled product is stable and does not rock.
Never leave the appliance unattended when lit.
If there is a leak on your appliance (smell of gas), turn off the gas supply, firstly at the gas
cylinder and then on your appliance by turning the respective knobs fully clockwise. Take
them outside immediately into a well-ventilated flame-free location where the leak may be
detected and stopped.
This appliance consumes oxygen and needs ventilation for optimum performance and for
safety of those in close proximity.
Room ventilation is important for the efficient performance of the appliance and for the
safety of the occupants in the room.
The room where this appliance is used should have a window or a door that can be opened
or partially open during use. If there is no window or door available for room ventilation,
extra ventilation must be installed for your sefety.
If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks
using a flame, use soapy water. The correct way is to smear the joints with soapy water. If
bubbles form then there is a gas leak. Immediately turn off the gas supply first by closing the control valve on the gas cylinder and
then the appliance valve, check that all the connections are properly fitted. Re-check with soapy water. If a gas leak persists return the
product to your CADAC dealer for inspection / repair.
Do not modify the appliance. Do not use it for anything for which it has not been designed.
During use, parts of the appliance will become hot (particularly the burner) Avoid touching hot parts with bare hands. The use of
gloves is recommended.
Keep young children away from the appliance at all times.
Do not twist or pinch the hose.
Do not move the appliance during use.
Do not use the appliance without the Potstands being in place and properly located.
Turn off the gas supply at the gas container after use.
Do not modify the appliance, any modification may be dangerous.
CAUTION
must be provided.
IMPORTANT
Retain these instructions for future reference.