HoMedics BPA-065 Manual Del Usuario página 29

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Recommended separation distances between portable and mobile RF communication equipment
and the device.
The device is intended for use in an electromagnetic environment where radiated RF disturbances are
under control. User can help prevent electromagnetic interference by keeping the device at a minimum
distance from portable and mobile RF communications equipment (transmitters). The table below details
the maximum output power of transmitter:
Rated maximum
output power of
transmitter
W
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can
be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from
structures, objects and people.
• Guidance and manufacturer's declaration – electromagnetic immunity
The device is intended for use in the electromagnetic environments listed below, and should only be used
in such environments:
Immunity test
IEC 60601 test level
Conducted RF
3V rms
IEC 61000-4-6
At 0.15-80 MHz
6V rms
At ISM & Radio Amateur
Freq.
Radiated RF
10 V/m at 80-2700 MHz
IEC 61000-4-3
AM Modulation And 9-28V/
(Proximity fields
m at 385-6000MHz,Pulse
from RF wireless
Mode and other Modula-
communications
tion. The system shall
equipment
be tested as specified in
IEC 61000-4-3)
IEC60601-1-2 Table 9 for
proximity fields from RF
wireless communications
equipment using the test
methods specified in IEC
61000-4-3
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflec-
tion from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above,
the device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be
necessary, such as reorienting or relocating the device.
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Separation distance according to frequency of transmitter m
150 kHz to 80 MHz
d = 1.2
0.12
0.38
1.2
3.8
12
Compliance
3V rms
At 0.15-80 MHz
6V rms
At ISM & Radio Amateur
Freq.
10 V/m at 80-2700 MHz
AM Modulation And 9-28V/
m at 385-6000MHz,Pulse
Mode and other Modula-
tion. The system shall
be tested as specified in
IEC60601-1-2 Table 9 for
proximity fields from RF
wireless communications
equipment using the test
methods specified in IEC
61000-4-3
80 MHz to 800 MHz
d = 1.2
0.12
0.38
1.2
3.8
12
Electromagnetic environment –
level
Portable and mobile RF communications
equipment should be used no closer to any
part of the device, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.
Recommended separation distance
d = 1.2
d = 1.2
d = 2 .3
where P is the maximum output power rating
of the transmitter in watts (W) according to
the transmitter manufacturer and d is the
recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey, a
should be less than the compliance level in each
frequency range.b
Interference may occur in the vicinity of
equipment marked with the following symbol:
28
800 MHz to 2.7 GHz
d = 2.3
0.23
0.73
2.3
7.3
23
guidance
80 MHz to 800 MHz
800 MHz to 2.7 GHz

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido