INSTALLATION GUIDE
1.
Attach system head to cartridge to help determine
under sink placement.
INSTALLMENT ORIENTATION:
Suggested installation orientation is
vertically mounted.
2.
Locate a suitable area under the sink to mount the
system, noting that three (3) inches of clearance
from the base of the cartridge is needed for easy
cartridge replacement. The System Head must be
installed less than three (3) feet from the cold-water
inlet valve.
3.
After determining placement, remove Cartridge
from System Head. Place System Head in desired
mounting location and use a pencil to mark the top
left mounting hole. Use a level and measuring tape
to mark the remaining holes for System Head and
Cartridge Mounting Brackets.
4.
After penciling in the mounting placement, use a 7/32" drill bit to drill holes for plastic anchors.
Carefully tap anchors into the drilled hole with a hammer.
5.
Using a Philips head screwdriver, mount the System
Head and Cartridge Mounting Brackets using the
provided screws.
5
PSWFUC100 Under-Counter Faucet Filter Owner's Manual
3"