4.0 MAINTENANCE
During the working life of the unit, it should require little or no maintenance. However, if abnormal or unusual
environmental conditions occur due to plant damage or accident etc., then visual inspection is recommended.
If the unit requires cleaning, then only clean exterior with a damp cloth to avoid electro-static charge build up.
If a unit fault should occur, then the unit can be repaired by MEDC. All parts of the unit are replaceable.
If you acquired a significant quantity of units, then it is recommended that spares are also made available.
Please discuss your requirements with the Technical Sales Engineers at MEDC.
5.0 CERTIFICATION/APPROVALS
IECEx units
Certified to IEC 60079-0, IEC 60079-1 and IEC 60079-31
Ex d unit (IEC certification No. IECEx BAS 09.0060)
Ex d IIC T6 (-55°C to +55°C) Gb
Ex tb IIIC T85°C (-55°C to +55°C) Db IP66/IP67
or
Ex d IIC T5 (-55°C to +70°C) Gb
Ex tb IIIC T100°C (-55°C to +70°C) Db IP66/IP67
The IECEx certificate and product label carry the IECEx equipment protection level marking
Gb
Db
Where:
Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.
Db signifies suitability for use in a Zone 21 surface industries area in the presence of dust
ATEX units
Certified to EN60079-0, EN60079-1 and EN60079-31
Ex d unit (ATEX certification No. Baseefa03ATEX0075)
Ex d IIC T6 (-55°C to +55°C) Gb
Ex tb IIIC T85°C (-55°C to +55°C) Db IP66/IP67
or
Ex d IIC T5 (-55°C to +70°C) Gb
Ex tb IIIC T100°C (-55°C to +70°C) Db IP66/IP67
The ATEX certificate and product label carry the ATEX group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
D Signifies suitability for use in the presence of dust
The ATEX certificate and product label also carry the following mark:
1180
This signifies unit compliance to the relevant European directives, in this case 94/9/EC, along with the number
of the notified body issuing the EC type examination certificate.
07/15
© MEDC 2015