Precautionary measures
The outside of the vacuum cleaner should be cleaned by dust
extraction procedures and wiped down, or should be treated with a
sealing agent before being removed from the hazardous area. All
parts of the vacuum cleaner must be considered to be contaminat-
ed when they are removed from the hazardous area, and suitable
handling must be used to prevent dust distribution.
Contaminated items
When carrying out maintenance or repair work, all contaminated
items which have not been adequately cleaned, must be disposed
of. Such items must be disposed of in impermeable bags in
accordance with the applicable regulations concerning the disposal
of such waste.
12.1 Testing the effectiveness of the vacuum
cleaner
There must be an adequate air exchange rate L in the room if the
exhaust air returns to the room. Further information can be taken
from your national regulations.
13
First aid in the event of a fault
Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault
Reduction in suction
Vacuum cleaner will not start
The vacuum cleaner does not start
when the tool is switched on in the
>AR< mode
PE emptying and disposal bag is sucked
against the filter
With inserted fleece filter bag, dust in
container
Do not take any other action and contact the central customer service workshop.
FVC_35M-v2.indb 23
If the suction of the vacuum cleaner reduces and the cleaning
procedure of the folding filter cassettes increases, the suction
performance is not adequate (provided that the container is empty
and the fleece filter bag has been replaced) then it is necessary to
replace the folding filter cassettes
12.2 Cleaning
Acids, acetone and solvents can damage parts of the vacuum
cleaner.
▶ Clean container and accessories with water.
▶ Wipe the top section with a damp cloth.
▶ Allow the container and accessories to dry.
12.3 Repair
Inappropriately repaired vacuum cleaners present a danger to
the operator.
Have repairs carried out by specialists, e. g. customer service.
Use only genuine spare parts.
NOTE
Possible cause
Filter contaminated
fleece filter full
Container full
Nozzle, pipes or hose blocked
Mains plug plugged in?
Mains power missing?
Mains cable OK?
Cover closed properly?
Water sensor switched off?
Vacuum cleaner in readiness for
operation "AR"?
Is the mains plug of the unit in the plug
socket?
Solenoid valve of compressed air
automatic switch-on contaminated?
Position of rotary slider incorrect
Position of rotary slider incorrect
(see see section
NOTE
l DANGER!
Remedy
Clean.
Change.
Empty.
Clean.
Set to "I" or "IR"
(see "2 Display and Operating
Elements").
Put the mains plug in the vacuum cleaner plug
socket
Flush the compressed air automatic switch-on with
alcohol
Set rotary slider to OPEN
(see "8.4 Inserting PE
emptying and disposal
bag").
Set rotary slider to CLOSE
(see "8.3 Inserting fleece
filter
bag").
9.1).