Malfunctions
Malfunction
Machine without function
Pad does not turn
Machine has no function, indicator
light is on
Machine does not reach nominal
speed, overcurrent is activated
Machine does not run smoothly
Technical data
Machine
Working width
Dimensions (LxWxH)
Maximum weight of operational machine
Rated voltage
Frequency
Rated power, nominal
Values according to IEC 60335-2-67
Sound pressure level LpA
Uncertainty KpA
Vibration
Uncertainty K
Splash water guard
Protection class
Accessories
No.
Item
7521297
One-way fleece dust bag
Various pads (pink, red or special pads)
66
Possible causes
Machine is switched off
No power supply
Main cord defect
Motor does not turn
Foot pedal is locked
Defective safety switch
Motor runs, but tool does not rotate
Defective electronic component
Machine overload, overload switch
was activated
Machine overload
Undervoltage: Main cord is too long
Pad deformed or damaged
ergodisc 2000
50
108 x 59 x 119
54
220-240V~
50
1500
Troubleshooting
• Switch on the main switch
• Insert the plug into the mains sock-
et
• Replace the main cord
• Contact your service partner
Unlock the foot pedal
• Contact your service partner
• Drive belt torn or loose
• Contact your service partner
• Contact your service partner
• Wait a few minutes and try again
(overload switch resets automati-
cally)
• Check the work technique
• Remove power supply cord exten-
sion
• Check the voltage rating
• Replace pad
100-120V~
220V~
60
60
68
2.5
<2.5
0.25
IPX0
I
Page
61
63
62
cm
cm
kg
AC
Hz
W
dB(A)
dB(A)
m/s2
m/s2