Samson DF250 Serie Guía De Servicio Técnico Y Mantenimiento página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

In this document you will find warnings and cautions for installation, use
and maintenance of the Direcflo
This symbol aware that there is a danger of serious bodily injury or death
if you ignore the warning described.
• This equipment is for professional use only.
• Do not degrade the integrity of the equipment. Use only original
replacement components from Samson Corporation.
• Fluids not suitable for the pump can cause damage to the pump unit
and involve risk of serious personal injury.
• Always consult Samson Corporation. if you have any questions about
the compatibility within the fluids and the pump materials, including
elastomers.
• Install and use the pump according to all local and national regulations
and abide all health and safety laws or legislation.
• The pump can produce fluid pressures equal to the air supply pressure.
Do not exceed the maximum allowable pressure of 100 psi (7 bar) air
supply. The total hydraulic pressure (differential pressure + system)
should never exceed 100 psi (7 bar).
• Never use a pump that leaks, that is damaged, that is corroded or
otherwise it may lack the capacity to contain the fluid.
• Frequently check that the bolts on the diaphragm cover of the pump are
torqued correctly.
Air operated double diaphragm pumps are air-powered, reciprocating
positive displacement pumps with two pumping chambers. Two
diaphragms, centrally located in the chambers, separate the compressed
air (dry side) from the fluid being pumped (wet side). A shaft transmits
the reciprocating motion of one diaphragm to the other. A directional valve
alternatively distributes the air from one chamber to the other; thus a
reciprocating movement of the diaphragms is created. With each stroke,
fluid is discharged by one of the diaphragms whilst the opposite
diaphragm sucks new fluid into the expanding chamber. Check valves,
two on the discharge side and two on the suction side, control and direct
the fluid flow.
2
855 829 R. 10/16
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa USA • Phone (828) 686-8511 • Fax (828) 686-8533
Warnings and cautions
pumps.
®
Warning
Carefully read the instructions and warnings before operating the equipment!
Here's the meaning of symbols you may find in this document and
general warnings that you should keep in mind.
This symbol aware that there is a danger of personal injury or property
damage if you ignore the caution described.
Warning
Do not use a model with aluminium wetted surfaces to pump fluids for
human consumption, there is a possibility of trace contamination of lead.
Danger of explosion if used 1,1,1-trichloroethane, methylene chloride or
other halogenated hydrocarbon solvents with aluminium wetted materials.
It could cause serious injury and property damage.
Inside the pump, diaphragms separate the fluid that is being pumped from
the air supply. If a diaphragm breaks, the fluid can leak out of the air
exhaust and contaminate the environment.
When handling hazardous fluids, always route the air exhaust into a
suitable container and locate it in a safe place.
When the fluid source level is situated higher than the pump, (flooded
suction), the outlet tank must be at a higher level than the product to
prevent spills.
For pumps handling hazardous fluids that are a danger to humans or to
the environment, install a suitable container surrounding the pump to
prevent any leaks or spills.
Ensure that the operators of this equipment are trained on the operation
and limitations. Use safety equipment as safety goggles or other
equipment required.
Description
Material
PTFE
NBR
Acetal
Hytrel
®
Neopreno
Santoprene
®
Viton
®
Polypropylene
®
Caution
Temperature range
5 ºC - 105 ºC / 41 ºF - 221 ºF
10 ºC - 80 ºC / 50 ºF - 176 ºF
10 ºC - 90 ºC / 50 ºF - 194 ºF
10 ºC - 90 ºC / 50 ºF - 194 ºF
-18 ºC - 93 ºC / 0 ºF - 200 ºF
-29 ºC - 135 ºC / -20 ºF - 275 ºF
-10 ºC - 120 ºC / -4 ºF - 248 ºF
10 ºC - 80 ºC / 50 ºF - 176 ºF