Installation; Opening The Units; To Open The Outdoor Unit; Mounting The Outdoor Unit - Daikin Alterna EVLQ05CAV3 Manual Del Instalacion

Tabla de contenido

Publicidad

4 Installation

The outdoor unit is designed for outdoor installation only, and for
ambient temperatures ranging 10~43°C in cooling mode and –
25~25°C in heating mode.
4
Installation
4.1

Opening the units

4.1.1

To open the outdoor unit

DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
2
2
4.2

Mounting the outdoor unit

4.2.1

To provide the installation structure

If the unit is installed directly on the floor, prepare 4 sets of M8 or
M10 anchor bolts, nuts and washers (field supply) as follows:
INFORMATION
The maximum height of the upper protruding part of the
bolts is 15 mm.
(mm)
In any case, provide at least 300  mm of free space below the unit.
Additionally, make sure the unit is positioned at least 100 mm above
the maximum expected level of snow. In this case, it is
recommended to construct a pedestal, and on this pedestal install
the EKFT008CA option kit.
Installation manual
4
1
b
(mm)
a
Maximum snowfall height
b
EKFT008CA option kit
If the unit is installed on brackets to the wall, it is recommended to
use the EKFT008CA option kit and to install the unit as follows:
b
(mm)
a
Maximum snowfall height
b
EKFT008CA option kit
Daikin Altherma hybrid heat pump – outdoor unit
EVLQ05+08CA
4P344906-1D – 2020.10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Alterna evlq08cav3

Tabla de contenido