THIS INSTRUCTIONS MUST BE READ BEFORE ANY USE OF THIS APPLIANCE
VBX RANGE: WORKING PRINCIPLE
Mainly made for Personal Protection Equipment (PPE) this sterilization cabinet provides an
excellent virucidal (NF T 72-281) decontamination of every object or accessory placed inside.
The automatic sterilization cycle's management (patented), factory settings, controls the UV-C
bulbs (253nm) located inside the cabinet. Their UV-C radiation destroys the germs by degrading
the exposed cells.
Warning : Decontamination destroys the germs but is not a cleaning method.
The virucidal and bactericidal results are only achieved with a complete cycle.
USE
Open the VBX door and place in the cabinet the objects to decontaminate, then close the door.
The VBX automatically begins a sterilization cycle of 30 minutes (fixed duration).
If the door is opened and closed before the end of a cycle, the device reinitializes a complete
cycle. At the end of the cycle, the utensils are decontaminated and ready to use.
Two lights indicators show the device state:
GREEN OFF + RED OFF → the door is open or incorrectly closed
-
GREEN OFF + RED ON → A sterilizing cycle is processing
-
GREEN ON + RED OFF → Sterilization is complete, utensils are ready to use
-
IMPORTANT
This appliance can be used by children older than 8 years and by persons with diminished
physical, sensory or mental capacities or no experience, only if they are correctly supervised or
if they have been given the instructions on how to use the appliance with complete safety and if
they understand the risks involved. Children must not play with this device. This device must be
placed out of touch from children (seen "POSITIONING") Cleaning and servicing must not be
undertaken by the user without knowledge of the specific processes (A2 / EN 60335-1).
IMPORTANT
This appliance can be used by children older than 8 years and by persons with diminished
physical, sensory or mental capacities or no experience, only if they are correctly supervised or
if they have been given the instructions on how to use the appliance with complete safety and if
they understand the risks involved. Children must not play with this device. This device must be
placed out of touch from children (see "POSITIONING") Cleaning and servicing must not be
undertaken by the user without knowledge of the specific processes (A2 / EN 60335-1).
POWER REQUIREMENTS
VBX sterilizers are designed to operate from the following power supply: 220/240V – 50/60Hz.
Therefore, please ensure that the electricity supply in your premises is compatible with this device.
This appliance must imperatively be connected to an electric socket that is earthed and
equipped by protective a 30mA residual-current device (RCD).
PHOTOBIOLOGICAL SAFETY
Page 3 sur 4
BRC SAS – 21 rue des coteaux de Grand Lieux – 44830 BOUAYE
info@brcsa.com - Tel. 02 40 34 57 24 – Fax. 02 40 34 74 76 – www.brcsa.com
NEVER use UV-C bulbs out of this enclosure.
NEVER start this device if it appears to be damaged.
NEVER attempt to activate the "switch on" when the appliance's door is open.
POSITIONING
This device is only made to be used indoors and must be installed in vertical
position. It has to be fixed to the wall at an approximate height of 1.30m,
preferably in an accessible and clean area. The units must only be used in areas
which are free of dust and possible explosive vapour mixture. Should you have
any queries contact your local reseller for advice before installation.
INSTALLATION
1. Fix the 3/4 screws and plugs
2. Hang the device by sliding screw's heads into corresponding holes
3. Open the door and tighten the screws
to fix firmly to the wall
4. Connect the appliance to a power outlet
corresponding to the power requirements
5. A sterilizing cycle will start automatically.
SERVICING
Changing of the UV-C bulb by any non-qualified user is strictly forbidden. Before any form
of servicing, even like bulb replacement, the unit must be disconnected from the mains supply.
To maintain the sterilizing efficiency, the UV-C bulbs have to be replaced annually.
CLEANING
The internal cleaning of this device can only be made by using a slightly damp towel. Avoid
spraying water directly inside the device. For external cleaning the unit can be sprayed (low-
power) with water to clean. It is important that the doors remained closed.
GUARANTEE
Your unit is guaranteed for 2 years (excluding bulbs replacement). If a fault occurs, contact your
supplier, who will replace your unit checking that the product has been operated under normal
conditions.
CHARACTERISTICS
Power
Virucidal Effect
* average value in Virucidal certificate NF T 72-281
Lamp
VBX 15
1x15W
VBX 25
1x25W
VBX 30
2x15W
VBX 50
2x25W
SUPPORT
A PPE (Masks and glasses etc.)
D small tools – 2 shelves
19.05.2020
4
Page 4 sur
Indice F
This device uses a bulb emitting UV-C. UV-C radiations are harmful to eyes and
skin. The constructions of the appliance ensures the user's complete safety
against these radiations under normal usage conditions. Furthermore, a micro-
switch cuts the power of the bulb each time the door is opened. Unappropriate
usage or structural damage may cause some exposure to UV-C rays.
380
VBX15/25
210-240VAC 50/60Hz Lifetime
4.65 log *
Pre-set lifecycle
Length
30 min
496mm
3 min
496mm
30 min
939mm
3 min
939mm
C
small tools – 1 shelf
K
Kitchen tools
BRC SAS – 21 rue des coteaux de Grand Lieux – 44830 BOUAYE
info@brcsa.com - Tel. 02 40 34 57 24 – Fax. 02 40 34 74 76 – www.brcsa.com
800
VBX30/50
6000h
Width
Height
Weight
220mm
404mm
6.5Kg
220mm
404mm
6.5Kg
220mm
404mm
11.5Kg
220mm
404mm
11.5Kg