NEXA INOX ART 7W G2+ VIDEO DOOR ENTRY SYSTEM KIT - VILLAS
SAFETY PRECAUTIONS
- Always disconnect the power supply before making modifications to the device.
- The installation and handling of these devices must be carried out by authorised personnel.
- The wiring must run at least 40 cm away from any other wiring.
- In the power supply unit:
w
Do not overtighten the screws on the connection block.
w
Install the power supply in a dry and protected place free without risk of drip or water projections.
w
Avoid locations that are humid, dusty or near heat sources.
w
Do not block ventilation holes of the equipments so that air can circulate freely.
w
To avoid damage, the power supply has to be firmly fixed.
w
To prevent electric shock, do not remove the cover or handle the wiring connected to the terminals.
( )
*
CHARACTERISTICS
- Video door entry system with simplified installation (non-polarised 2 wire bus).
- Up to 4 access panels (DPM-G2+ distributor required for more than one access panel) per installation.
- Maximum 1 apartment (KIT NX5110 ART 7W 1P) per installation.
- The max. number of monitors/audio terminals in the apartment is 4 (master, slave1, slave2 & slave3).
- Maximum 4 ART 7W monitors / audio terminals in parallel (without distributors) in the apartment.
- Wifi transmission ART 7W monitor to call transfer to mobile smartphone.
Note: To activate and configure monitor call forwarding, see manual "TART 7W" cód. 50122463.
Only the master ART 7W monitor can activate WI-FI transmission.
- Call confirmation tone.
- Visual indications on the door panel for people with impaired hearing (indicating call process,
communication, door open and channel busy).
- Audible indications on the door panel for people with impaired vision (indicating call is in progress,
resident unavailable, door is open, communication is finished and system is busy, try later).
SYSTEM OPERATION
- To make a call, the visitor must press the call button of the apartment; an audible sound indicates
that the call is being made and door panel LED
is in progress' message appears indicating that a call is being made. At this moment, the
apartment's monitors receive the call.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
the image from slave monitors 2 or 3, press the screen for the image to appear. If the call is not
answered within 45 seconds, LED
will turn off and the system will become free.
- If call transfer to your mobile phone has been programmed, you can cancel the transfer at any
time from the monitor, with it being necessary to communicate with the door panel from the main
menu.
-
To establish communication, press off-the-hook icon
off and the led
will
turn on
.
- Connection will last for 90 seconds or until on-the-hook icon
communication ends, LED
will turn off and the system will become free. If vocal synthesis is
enabled, a 'Communication is finished' message will indicate that the call is over.
- To open door
or
of the door panel, press the corresponding icon on the screen during the call
2
1
or communication processes: one press will activate the lock release for 3 seconds and LED
also turn on for 3 seconds. If vocal synthesis is enabled, a 'Door is open' message will be indicated
on the door panel.
- Detailed operation of the monitor, see
"TART 7W" cód. 50122463.
( ) For more information see "TKIT632 ART 7W WIFI (code 50122637)" manual.
*
https://doc.golmar.es/search/manual/50122637
will turn on. If vocal synthesis is enabled, a 'Call
displayed on the screen will blink green. To view
on the screen. Door panel LED
will turn
is pressed on the screen. When
will
manual
.
EN
2
NEXA INOX ART 7W G2+ VIDEO DOOR ENTRY SYSTEM KIT - VILLAS
( )
DOOR PANEL INSTALLATION
*
Positioning the embedding box:
Make a hole in the wall to position the top of the door panel at a height of 1.65m.
Hole dimensions CE-610 embedding box, 125(W) x 140(H) x 56(D) mm.
:
( )
Description of the EL632 G2+ SE module DIP switch:
*
( )
Description of the visual indications on the door panel.
*
( )
Description of the vocal synthesis / tones mode (audible indications on the door panel).
*
( )
Selecting the vocal synthesis language or tones mode of the EL632 G2+ SE module.
*
( )
Description of the P1 external button of the EL632 G2+ SE module:
*
( )
Change the call code of the P1 button of the EL632 G2+ SE module:
*
Audio level jumper description (vocal synthesis and tones mode) EL632 G2+ SE module:
Audio level jumper is located on the left side of the back module.
The jumper for volume control, allows to select between a minimum, maximum
or mute of the vocal synthesis and tones mode from the door panel.
1
2 3
( )
1
Jumper placed between 2 and 3, set to minimum volume the vocal
synthesis and tones from the door panel.
1
2 3
Jumper placed between 1 and 2, set to maximum volume the vocal synthesis and
tones from the door panel.
1
2 3
Jumper removed, set to mute volume the vocal synthesis and tones from the door panel.
( )
1
Factory default.
Description of the door panel LED lights (for low light conditions):
The door panel lighting LEDs will turn on during a call if the door panel
lighting at that moment is low. This enables the user to view the person
who has called from the apartment monitor.
( )
LOCK RELEASE INSTALLATION
*
Lock release installation instructions:
If the lock release is to be fitted to a metal door, use a Ø3.5mm drill bit and
thread the hole made. For wooden doors, use a Ø3mm drill bit.
IMPORTANT: The lock release must be Golmar 12V AC or DC.
AC lock release (TF-104 power supply required), fit the varistor supplied
with the kit directly to the lock release terminals to ensure the device
functions correctly.
( ) For more information see "TKIT632 ART 7W WIFI (cód. 50122637)" manual.
*
https://doc.golmar.es/search/manual/50122637
1850
1650
1450
3.5 x 25
DIN-7972
( )
With the
*
M 4 x 8
DIN-963
3
( )
1
1
2 3
1
_
+
C1 NA1
Relé 1
EN

Publicidad

loading

Este manual también es adecuado para:

50122637