Inspection, Maintenance, Disposal; Maintenance / Repair; General Instructions - Siemens SP Serie Manual De Instrucciones

Motorreductores-engranaje planetario
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
7

Inspection, Maintenance, Disposal

7.1

Maintenance / Repair

7.1.1

General instructions

Clean wherever and whenever the degree of contamination makes it necessary in order
to ensure that the waste heat is adequately dissipated.
As the operating conditions vary greatly, one can only cite general intervals for fault-free
operation.
Guidelines:
- Bearing service life 20,000 hours
- Radial shaft seals aprox. 5,000 hours with oil lubrication
The motors' rotors contain permanent magnets with high magnetic flux densities
which exert strong attractive forces on ferromagnetic bodies.
People fitted with a heart pacemaker are at risk in the vicinity of a disassembled
rotor.
Data stored on electronic data media may be destroyed.
The encoder system must be readjusted each time after the motor has been
disassembled.
The maintenance of the geared motors is kept to a minimum by their design concept.
All components subject to operational wear (for example friction linings of brakes)
must be included in the regular maintenance measures. SIEMENS service partners are
available for all maintenance work on gears (see Chapter 6 "Instructions in case of
faults").
Safety rules for working in electrical installations as per
EN 50110-1 (DIN VDE 0105-100):
- Always work with the equipment electrically dead.
- Isolate from electrical supply.
- Secure against switching on again.
- Check electrical deadness.
- Earth and short-circuit.
- Cover or cordon off adjacent parts which are electrically live.
- Release for work.
- Connect the PE conductor to
Siemens AG
ENGLISH
Electric shock hazard!
When the rotor is rotating, there is a dangerous voltage at the motor
terminals. Stop the motor before commencing any electrical work.
Only use trained, qualified personnel for assembly work on the
converters and plugs.
Observe the regulations for working in electrotechnical plants.
610.40 072.01
WARNING
NOTICE
DANGER
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lp seriePle serieSp 210Sp 240

Tabla de contenido