Descargar Imprimir esta página

Kohler K-513-H2 Guia Del Usuario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

15-3/8"
(39.1 cm)
32" (81.3 cm)
1-5/8" (4.1 cm)
3-1/4" (8.3 cm)
Product Information
Applicable products:
Bath whirlpool – left drain hole (less grip
rails)
Bath whirlpool – right drain hole (less grip
rails)
Bath whirlpool – left drain hole (grip rails)
Bath whirlpool – right drain hole (grip rails)
Fixture*:
Bathing well:
Basin area
46" (116.8 cm) x 20" (50.8 cm)
Top area
53-3/4" (136.5 cm) x 24" (61 cm)
Weight
460 lbs (208.7 kg)
To overflow:
Water depth
10-3/4" (27.3 cm)
Capacity
45 gal (170.3 L)
* Approximate measurements for comparison only.
Pump
kW
1.5
* Approximate measurements for comparison only.
Minimum access panel:
Pump/control
1019456-1-D
8-1/2"
(21.6 cm)
60" (152.4 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
K-513-H2
K-514-H2
K-783-H2
K-784-H2
V
A*
240
11
required
32" (81.3 cm) W x 15" (38.1 cm) H
No change in measurements if connected with drain
illustrated. (K-7160-TF or K-7160M-TF)
K-783-H2
3/4" (1.9 cm)
16-1/4"
(41.3 cm)
1/4" (6 mm)
Required accessories:
Jet trim kit
Grip rails (pair)
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current
Device (RCD):
Pump/control
Locate the outlet behind the whirlpool and within 24"
(61 cm) of the pump.
Installation Notes
Install this product according to the installation guide.
Cast iron whirlpools are extremely heavy, making some drop-in
installations difficult. Splitting the deck/surround is recommended
if installing into a deck.
Floor support under whirlpool must provide for a minimum of
65 lbs/square foot (315 kg/square meter) loading.
2
Note:
Top view shown with grip rails.
Pump/Control Access
1-1/2" IPS Thread
1-1/2" IPS
220-240 V, 20 A, 50/60 Hz
K-9694
K-9620
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-514-h2K-783-h2K-784-h2