6. Assembling the tank dome and drinking water telescopic dome shaft
6.4 Drinking water lid
The drinking water telescope is provided
with a second lid that rests on top. This is
also always placed on the rim of the
telescope, except when working in the tank.
The seal must be in place in the groove
around the entire circumference before the
lower telescope lid is positioned.
ATTENTION: The upper drinking water lid
serves only as a protective cover and is not
safe to walk on!

6.5 Assembling the adapter

For lager coverage heights a adapter is needed. To insert the adapter
into the tank dome, soft soap is needed. Into the highest groove of the
adapter the profile seal is inserted an greased generously. Afterwards
push the drinking water telescopic dome shaft into the adapter and
adapt it to the planned area surface.
max. earth-cover 2000 mm
Drinking water lid
2
Telescopic dome shaft (can be inclined by 5°)
Adapter
Tank dome (can be rotated by 360°)
The entire system must be checked for leaks, cleanliness and stability at least every three months.
The entire system should be serviced at intervals of approx. 5 years. In this case, all parts of the system
must be cleaned and their function checked. Servicing should be carried out as follows:
Drain the tank completely
Clean surfaces and internal parts with water
Remove all dirt from the tank
Check that all internal parts are firmly seated.