INTRODUCTION
This pump is ideal for both residential and commercial lawn and turf
sprinkler systems. This pump is suitable for installations where the vertical
distance from the pump to the water level does not exceed 25 ft (7.6 m),
including drawdown (less at high altitudes). In offset installation, friction
losses in the suction pipe must be taken into consideration (refer to
Table 2, Friction Loss, page 8).
This instruction sheet provides you with the information required to
safely own and operate your product. Retain these instructions for
future reference.
The product you have purchased is of the highest quality workmanship and
material, and has been engineered to give you long and reliable service.
This product has been carefully tested, inspected, and packaged to ensure
safe delivery and operation. Please examine your item(s) carefully to
ensure that no damage occurred during shipment. If damage has occurred,
please contact the place of purchase. They will assist you in replacement or
repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL,
OPERATE OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS
BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE!
PLUG DESCRIPTIONS AND SOCKET SIZES
s
NOTICE
Do not use open style wrenches to loosen plugs.
!
Plugs may become damaged and difficult to remove.
Priming Plug
9/16" - 8 pt
Drain Plug
3/8" - 8 pt
VOLTAGE SETTING INSTRUCTIONS
To change the pump voltage from the factory setting of 230 volts,
a qualified electrician should:
1.
Disconnect the power supply to the pump.
2. Remove the cover from the motor terminal box.
FOR 1 HP MODELS
Changing voltage from 230 Volts to 115 Volts:
The cutout in the voltage change indicator will display 230 prominently,
as shown below. Insert a flat screwdriver into the black voltage change
indicator. To change from 230 Volts to 115 Volts, rotate the voltage change
indicator counterclockwise until 115 is displayed in the cutout.
Insert flat screwdriver here
Set to 230 V
Changing voltage from 115 Volts to 230 Volts:
The cutout in the voltage change indicator will display 115 prominently,
as shown below. Insert a flat screwdriver into the black voltage change
indicator. To change from 115 Volts to 230 Volts, rotate the voltage change
indicator clockwise until 230 is displayed in the cutout.
230
Insert flat screwdriver here
Set to 115 V
3
Motor Terminal Box Cover
230
230
Set to 115 V
Set to 230 V
230