4)
7)
Fig. 3
Attaching the extraction hose
1 Install the connecting tube and pull the sleeve over the connecting tube until it covers the metal flange.
The sleeve must be on the plastic tube so that it subsequently creates a seal with the metal flange.
2 Fold the sleeve down halfway, so that the metal flange is protruding at the top.
3 Feed the extraction hood's electric cable through the connecting tube from the bottom.
4 Insert the extraction hood into the connecting tube and rotate it once to secure it in place.
5 Place the clamp over the metal flange and attach it loosely, (no Fig.)
6 Slide the connector over the profile tube until the screw holes are aligned and then secure the connector to the profile
tube using the screw.
The electric cable must be protruding out of the metal flange.
7 Connect the electric cable on the profile tube with the electric cable of the extraction hood.
8 Use a cable tie to secure the connected cables on the profile tube, (no Fig.)
9 Trim any protruding ends of the cable tie, (no Fig.)
10Pull the extraction hose over the profile tube until it is over the metal flange.
11 Place the loosely attached clamp over the extraction hose and use the screwdriver to secure it in place. (no Fig.)
12 Fold over the bottom edge of the sleeve so that the clamp is covered. (no Fig.)
BAL.0733.0 • 2020-07-10
6 Putting into operation
6)
10)
EN - 11