INSTALLATION AND ASSEMBLY INSTRUCTIONS
VRC Series
IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR
FUTURE REFERENCE
SAFETY: This fixture must be wired in accordance with the NATIONAL ELECTRICAL CODE
and applicable local codes and ordinances. A person familiar with the construction and operation
of the product and the hazards involved must install this product. A qualified licensed electrician
should complete all work. Proper grounding is required for safety.
WARNING: Make certain power is OFF before installing or maintaining fixture.
RISK OF INJURY: Fixture may become damaged and/or unstable if not installed properly.
BOX MOUNTING
1. Remove refractor by loosening screws that attach the lens.
2. Remove LED Heat Sink assembly by removing 2 screws.
3. Remove knockout plug on the back of the fixture.
4. Drill appropriate points and attach using appropriate hardware
(not included).
5. Pull supply wires through mounting plate and attach to
mounting box.
6. Wire fixture as noted in the wiring section.
7. Reconnect assembly plug, install LED Heat Sink assembly,
reinstall refractor.
CONDUIT MOUNTING
1. Remove refractor by loosening screws that attach the lens.
2. Remove LED Heat Sink assembly.
3. Remove conduit access plug(s) on housing for desired conduit
entrance.
4. Secure fixture to ceiling using the appropriate hardware.
5. Attach conduit to fixture
6. Pull leads into fixture and make connections as noted in the
wiring section.
7. Reconnect assembly plug, install LED Heat Sink assembly,
reinstall refractor.
240-136LSI Rev. 03/17
WIRING
Note: LED fixtures utilizes a mult-volt (120-277V) that is auto
sensing, no rewiring is necessary.
1. Turn off electrical supply at the breaker.
2. Follow all local electrical codes for wiring and grounding
requirements.
3. Check to make sure that the supply voltage to the fixture is
compatible with the driver (120-277).
4. Connect the white fixture wire with white service wire.
5. Connect the black fixture wire to the black service wire.
6. Connect the green fixture wire to the ground wire.
7. Make sure all connections are secure using approved
connecting devices.
8. Turn on electrical supply at the breaker.
TROUBLESHOOTING
Check that:
1. The fixture is wired properly.
2. The fixture is grounded properly.
NOTE: Optional 0-10 V Dimming. Dimming provided through grey
& purple wires. Refer to control manufacturer for wiring
instructions.
Installation Questions?
Call LSI Field Service Department at:
1-800-436-7800 Ext. 3300
Fax: 1-877-861-1368
©2017 LSI Industries Inc.

Publicidad

loading

Resumen de contenidos para LSI VRC Serie

  • Página 1 7. Reconnect assembly plug, install LED Heat Sink assembly, & purple wires. Refer to control manufacturer for wiring instructions. reinstall refractor. Installation Questions? Call LSI Field Service Department at: 1-800-436-7800 Ext. 3300 Fax: 1-877-861-1368 240-136LSI Rev. 03/17 ©2017 LSI Industries Inc.
  • Página 2 Consulte el disipador de calor de LED, reemplace el refractor. fabricante para controlar las instrucciones de cableado. Preguntas de instalación? Llame al Departamento de Servicio de Campo de LSI en: 1-800-436-7800 Ext. 3300 Fax: 1-877-861-1368 240-136LSI Rev. 03/17...

Este manual también es adecuado para:

D-vrc