PEX CLAMP TOOL – THREE HANDLE
#865895
INSTRUCTION GUIDE
The PEX Clamp Tool will assemble 3/8", 1/2", 5/8", 3/4" and 1" stainless steel PEX clamps.
When used properly, closed Oetiker clamps meet ASTM F2098 Specification
CONNECTION ASSEMBLY
Cut the tube so that a clean, straight end is provided.
Slide the clamp over the tube end. Insert the fitting into
the tubing until the shoulder of the fitting contacts the
tubing end. Position the clamp 1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing.
Place the opened jaws of the PEX Clamp Tool over the raised ear of the clamp. Check to be sure that the
clamp is still properly positioned. Compress the tool handles until the first "click" is felt. The clamp is now
locked to the tubing. Compress the tool handles to complete the assembly. Note: The PEX Clamp Tool will
not release until the assembly is completed.
TOOL CARE
When used and maintained properly the PEX
Clamp Tool will provide years of trouble free service.
Failure to provide basic tool care and maintenance
will cause excess wear and possible premature
failure. The following should be adhered to in order
to maintain proper tool operation and Warranty
coverage.
Do not use the PEX Clamp Tool for any
purpose other than to assemble clamps.
Lubricate the tool head, spring and ratchet
mechanism once every thirty days with light
lubricating oil, if tool operation becomes
sluggish and after cleaning.
Clean tool periodically to remove rust and dirt.
CALIBRATION CHECK
Close handle to stop point
Insert gage into jaw gap
Gage must stop at no-go
If gage goes beyond this point re-calibrate tool
CALIBRATION PROCEDURE
Loosen adjustment nut
Place "Go" portion of gage into jaw gap
Rotate eccentric stud counter clockwise until
jaws contact gage
Tighten nut
Check tool with gage the first and last crimp
of each job site.
WARRANTY INFORMATION
When properly maintained and used as intended,
the PEX Clamp Tool is warranted against materials
and manufacturing defects for a period of 1 year
from date of purchase. This Warranty does not cover
defects or damage arising from improper installation,
lack of or improper maintenance, improper storage
or handling, ordinary wear and tear, misuse, abuse,
accident or use with unauthorized products or parts.
Liability is limited to repair or replacement of tool or
component parts which are determined defective as
covered by this Warranty.
US Patent # 8,312,755
IN THE EVENT OF
A JAM, COMPRESS
HANDLES TO
RELIEVE PRESSURE
ON RATCHET, PULL
RELEASE LEVER
IN DIRECTION OF
ARROW
United States: Oetiker, Inc.
6317 Euclid Street,
Marlette, Michigan 48453
T +1 800 959 0398
Info.us.marlette@oetiker.com
www.oetiker.com
DISTRIBUTED
BY RELIANCE WORLDWIDE
CORPORATION 2727 Paces Ferry Road SE,
Building II, Suite 1800,
Atlanta, GA 30339
T +1 877 700 4242
GAGE

Publicidad

loading

Resumen de contenidos para OETIKER PEX

  • Página 1 Position the clamp 1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing. Place the opened jaws of the PEX Clamp Tool over the raised ear of the clamp. Check to be sure that the clamp is still properly positioned.
  • Página 2 GUÍA DE INSTRUCCIONES La herramienta de sujeción para abrazaderas PEX monta abrazaderas PEX de acero inoxidable de 3/8", 1/2", 5/8", 3/4" y 1". Cuando se utilizan en forma adecuada, las abrazaderas Oetiker cerradas cumplen con las especificaciones de ASTM F2098.

Este manual también es adecuado para:

86589524694z