PRODUCT DATA SHEET
Item number
10035140, 10035141
PIN code
0063CO7365
Gas Heat Input
∑Qn(Hs)=11.2 kW
Gas
815 g/h
Consumption
Gas Category
I3+(28-30/37)
Gas Pressure
28-30
mbar
Type of Gas
Butane
Destination
BE-CY-CH-CZ-FR-
Countries
ES-GB-GR-IE-IT-
PT-SK-SI-TR
Injector Size
WARNINGS:
•
The appliance must be installed in accordance with
instructions and local regulations.
•
The use of this appliance in enclosed areas can be
dangerous and is PROHIBITED.
•
For use outdoors or in amply ventilated areas.
•
An amply ventilated area must have a minimum of 25 %
of the surface area open. The surface area is the sum of
the walls surface.
Chal-Tec GmbH
Wallstraße 16
10179 Berlin
Germany
I3B/P(30) I3B/P(50) I3B/P(37)
37 mbar
30 mbar
Propane
Butane,
Propane
and their
mixture
BE-CY-
CZ-DK-
EE-FI-
GR-IT-LT-
LV-MT-
NL-NO-
SE-SI-SK-
BG-RO-
TR
1.6 mm
1.6 mm
(1.6)
(1.6)
50 mbar
37 mbar
Butane,
Butane,
Propane
Propane
and their
and their
mixture
mixture
AT-CH-
PL
DE
1.4 mm
1.5 mm
(1.4)
(1.5)
I3P(37)
I3P(50)
37 mbar
50 mbar
Propane
Propane
CZ-FR-
AT-CH-
GB-GR-
DE-NL
IE-PT
1.6 mm
1.5 mm
(1.6)
(1.5)
0063-20
EN
49