5. DMX CONNECTION AND DMX PROTOCOL

DMX addressing

The device is controlled by universal DMX 512 pro-
tocol, DMX address is the start channel used to re-
ceive instructions from the external controller. For
independent control, each fixture must be assigned
its unique address control channels. For example,
this device has four channel modes: 11/13, if we set
the mode at standard 13 channels mode, and there
are several models need to be independently con-
trolled, we just simply address first fixture at 1, and
second fixture at 12, third one at 23, etc.
If the devices have the same address, they will be-
have synchronically.
DMX addressing is limited, don't set the address so
high that without enough control channels for the
fixtures.
Display is flashing when no DMX signal is received.
Back
02~60m 02m
Flip
ON/OFF
User
Use1/Use2
Code
XXX
CHxx
XXX
Rdm Name
-Password-
PID Code
Basic Reload
ON/OFF
---Password---
XXX
All Reload
ON/OFF
This device is equipped with 3-pins DMX in and
out sockets only.
Pin 1 = GND | Pin 2 = Signal (-) | Pin 3 = Signal (+)
The termination is prepared by soldering a 120Ω
resistor between pins 2 and 3.