(mm)
a
Maximum snowfall height
RXS50+60 + RX50+60 + ARXS50~71
R410A split series
3P360062-1H – 2016.09
5.2.2
To install the outdoor unit
5.2.3
To provide drainage
Make sure that condensation water can be evacuated properly.
NOTICE
If the drain holes of the outdoor unit are blocked up,
provide space of at least 300 mm below the outdoor unit.
▪ Install the unit on a base to make sure that there is a proper
drainage in order to avoid ice accumulation.
▪ Prepare a water drainage channel around the foundation to drain
waste water surrounding the unit.
▪ Avoid drain water flowing over the footpath, so that it does not
become slippery in case of ambient freezing temperatures.
▪ If you install the unit on a frame, install a waterproof plate within
150 mm of the bottom side of the unit in order to prevent the
invasion of water in the unit and to avoid the drain water dripping
(see the following illustration).
▪ Use a drain plug for drainage if necessary.
b
a
a
Drain hole
b
Drain plug
c
Bottom frame
d
Drain hose (Ø16 mm, field supply)
5.2.4
To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1 Prepare 2 cables as indicated in the following illustration (field
supply).
2 Place the 2 cables over the outdoor unit.
5 Installation
4× M8/M10
c
d
Installation manual
11