Storage - Dyna-Glo RMC-FA150NGDGD Manual De Instrucciones De Operación Y Lista De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Dyna-Glo Delux Operating Instructions and Parts Manual
Model RMC-FA150NGDGD
section. Repair any leaks immediately.
Maintenance (Continued)
2. Always keep heater clean. Clean
the heater annually, or as often as
needed to remove any dust or debris.
When the heater becomes dirty, wipe
it down with a damp cloth.
3. Keep the inside of the heater
free from foreign objects and
combustibles.
4. Have the heater inspected annually
by a qualified service person.
SERVICE PROCEDURES
Never service heater
WARNING
while hot, operating
or connected to the gas supply. Severe
burns or electrical shock may occur.
REMOVING PROTECTIVE COVER
1. Remove base lower at the bottom of
the heater.
Base
Base Lower
Figure 4 – Protective Cover Removal
2. Remove fan guard.
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST
FAN
IMPORTANT: Always remove the fan
from the motor shaft before removing
the motor assembly from the heater.
This will help prevent damage to the
fan.
1. Remove base lower.
2. Remove fan guard.
3. Remove base.
4. Disconnect lead wires attached to
the motor.
5. Remove motor assembly.
6. Loosen fan setscrew using a 1/8"
(3.2 mm) hex wrench, and remove
fan.
7. Using a soft cloth moistened with
kerosene or a cleaning solvent,
carefully clean the fan blades
making sure not to bend them.
8. Dry fan with clean cloth.
9. Assemble fan on motor shaft and
tighten hex nuts firmly (be careful
Fan Guard
not to overtighten).
10. Reconnect lead wires as shown in
the Wiring Diagram (Figure 6).
11. Reassemble base, fan guard and
base lower.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Washer
Hex Nut
Figure 5 – Fan Motor Shaft, Hex Nut
IGNITOR
The only maintenance necessary
for the ignitor is to be sure that the
gap between the electrodes is kept
between .10" and .15" (2.54 - 3.81 mm).
The ignitor is accessible through the
combustion chamber.

Storage

supply.
1. Replace the plastic caps over the
fittings they were installed when you
originally unpacked your heater.
2. Store the heater in a safe, clean and
dry location.
3. When removing the heater from
storage, always check inside of the
heater for any foreign objects left
by spiders or small animals. Keep
the inside of the heater clean from
foreign objects and combustibles.
5
Fan
Location
CAUTION
Always disconnect
heater from gas
www.ghpgroupinc.com
PROFESSIONAL GRADE
Motor

Publicidad

Tabla de contenido
loading

Tabla de contenido