Trouble Shooting - Premium PRN91DX Manual Del Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before requesting any service on your unit, please check the following points.
Please note that this guide serves only as a reference for solutions to common
problems.
SYMPTOM
POSSIBLE CAUSE
Compressor
Fuse blown or circuit breaker tripped.
not running.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Condensing
Excessive amount of warm product
unit runs for
placed in cabinet.
long periods
Prolonged door opening or door ajar.
of time.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Cabinet
Thermostat set too warm.
temperature
is too warm.
Blocking air flow.
Excessive amount of warm product

TROUBLE SHOOTING

CORRECTIVE ACTION
Replace fuse or reset circuit
breaker.
Plug in power cord.
Set thermostat to lower
temperature.
Wait for defrost cycle to finish.
Allow adequate time for product
to cool down.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
Ensure gaskets are snapped in
completely. Remove gasket
and wash with soap and water.
Check condition of gasket and
replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat
is not set too cold. Ensure that
door gasket(s) are sealing
properly.
Set thermostat to lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure there
are at least four inches of
clearance from evaporator.
Allow adequate time for product
9