5. General description of the
machine
5.1 Machine illustrations and type descriptions
(see page *1*)
• ETS 150 [ 5.0 ] / ETS 150 [ 2.5 ]
5.2 Operating elements and main components
(see page *1*)
A
– Random Orbital Sander ETS 150
B 01 – control housing - consisting of:
B 02 – front control housing (with rubber-
ised grip area)
B 03 – rear control housing (grip area)
C 01 – motor housing
D 01 – operating lever
E 01 – operating unit - consisting of:
E 02 – speed control [ + ]
E 03 – speed display [4; 5; 6; 7; 8; 9; A]
E 04 – speed control [–]
E 05 – On/Off switch
F 01 – connection cable
G 01 – driving disc
H 01 – sealing collar
J 01 – drive shaft with key areas for spanner
(provided)
K 01 – extractor hose connection
L 01 – spanner
5.3 Commissioning (see page *1* and *2*)
Caution! The mains plug must be discon-
nected from the mains socket and must not
be plugged into the mains socket for all works
described in the following!
a. Remove the power tool from its packaging.
b.  Attach a suitable OEM abrasive centrically on
the driving disc of the machine. Make sure that the
driving disc is securely attached.
Caution! The extraction openings of the
abrasive must be placed directly over the
openings in the driving disc to minimise dust
production during operation.
c. The electric power tool does not come with its
own extraction unit. Attach a MENZER industrial
extraction system with an extractor hose diameter
of 32 mm to the extractor hose connector. You
can optionally use the MENZER universal adapter
for third-party devices (Accessory – see page *2*)
to attach the power tool to an extractor connec-
tor with a different diameter. Make sure that a
suitable dust bag suitable for fine dust collection is
inserted in the industrial extraction unit.
Use an anti-static extractor hose. Doing so
will reduce the risk of static charge.
d.  Make sure that the operating lever is not acti-
vated before connecting the power tool to mains
electricity via the mains plug.
EN 9