TESTINg
1. Remove the decorative cover plate (secured by
two small screws).
2. Pinch control panel cover at the indicated points
as shown in Figure 5. Pull to remove cover.
Decorative
Cover
Plate
Pinch Here
Figure 5 - Removing Control Panel Cover
TrOuBLEShOOTINg wIrINg CONNECTIONS
wArNINg: Turn power off at the circuit breaker before rewiring.
If light does not
1.
turn on:
If light turns on in
2.
only one position
of remote switch:
If light turns
on with remote
3.
switch in either
position:
3. For test purposes, use a small, phillips screw-
driver to turn the TIME control to the TEST
(5 second) position (see Figure 6). Turn the
power back on at the circuit breaker.
4. Verify the switch has power. The bottom LED
will be lit.
5. Allow the sensor to stabilize (about 1 minute).
The sensor is ready to detect motion.
6. Push the ON/OFF button. The lights and mo-
tion sensor will turn on. The lights will remain
on as long as the sensor detects motion or the
ON/OFF button is pushed again. The lights
will turn off 5 seconds after motion stops.
Pinch Here
Figure 6 - Control Panel
Exchange* Control's
Red ⇔ Black wires.
Exchange* Control's
Red ⇔ Brown wires.
Wait for the unit to warm up (up to 1
minute). If the remote switch can turn
the lights on, it's OK. Otherwise:
Exchange* Control's
Black ⇔ Brown wires. Remove the
tape. Go to the next page.
6
T I M E
Test again. Go
Test again. Go
5
1
10
Test
15
25
to 2 or 3.
to 1 or 3.
598-1233-03