EN
INSTALLATION
1.5 POSITIONING OF THE OVEN
The place where the oven will be installed
must comply the following requirements:
• Be protected from atmospheric agents
and have an adequate air circulation;
• Comply with regulations concerning
safety at work;
• Have a room temperature between 5
°C and 35 °C with a humidification not
higher than 70%.
• Place the oven and proceed with level-
ling using adjustable feet.
*Keep a suitable distance at the back,
in order the label of equipotential clamp
is easy to see when the oven has been
installed.
The same clamp must be easy to access to install equipotential cable after the oven has been installed in com-
pliance with our instructions. Install the appliance in a position that allows access to the right side for installa-
tion, maintenance and technical assistance. Maintain the minimum distances between the oven walls, (rear and
right side) and either the brick walls or the other appliances.
VERY IMPORTANT: the oven must lay on a fireproof surface. If it is not so, place a sheet of stainless steel or
other fireproof material between the oven and the support surface.
1.6 ELECTRICAL CONNECTION
When the appliance is delivered it is set to work at the voltage given
on the rating plate affixed on the right side of the appliance.
The effectiveness of the equipotential system of which the appliance is
part of, must conform to current standards.
Connect using the screw you find in the back side of the oven, marked
with the word EQUIPOTENTIAL.
The Manufacturer declines all and every responsibility if this important
accident prevention norm is not complied with. If the feeding cable is
damaged, it must be replaced by the technical service or in any case
by similar qualified personnel, in order to avoid any risk.
1.7 TECHNICAL DATA FOR ELECTRICAL CONNECTION
Model
4 x 1/1 GN- 60x40
Electric
5 x 1/1 GN- 60x40
Electric
6 x 1/1 GN- 60x40
Electric
7 x 1/1 GN- 60x40
Electric
10 x 1/1 GN- 60x40
Electric
12 x 1/1 GN- 60x40
Electric
4 x 1/1 GN- 60x40
Gas
5 x 1/1 GN- 60x40
Gas
6 x 1/1 GN- 60x40
Gas
7 x 1/1 GN- 60x40
Gas
10 x 1/1 GN- 60x40
Gas
12 x 1/1 GN- 60x40
Gas
Power loading
no. and motor
and voltage
7.5 kW
380 - 415 V 3N~
1 x 240 W
50 Hz Analog
50/60 Hz Touch
10.9 kW
380 - 415 V 3N~
1 x 240 W
50 Hz Analog
50/60 Hz Touch
18.4 kW
380 - 415 V 3N~
2 x 240 W
50 Hz Analog
50/60 Hz Touch
0.3 kW
220 - 240 V 1N~
1 x 240 W
50 Hz Analog
50 Hz Touch
0.3 kW
220 - 240 V 1N~
1 x 240 W
50 Hz Analog
50 Hz Touch
0.6 kW
220 - 240 V 1N~
2 x 240 W
50 Hz Analog
50 Hz Touch
> 3 cm
Heating
power
power
7.2 kW
10.6 kW
17.8 kW
--
--
--
12
> 10 cm (> 50 cm
)
Absorbed
Feed cable
current
section
11.5 A
5 x 2.5 mm
17.0 A
5 x 4.0 mm
28.0 A
5 x 6.0 mm
1.2 A
3 x 1.5 mm
1.2 A
3 x 1.5 mm
2.4 A
3 x 1.5 mm
*
2
2
2
2
2
2