6 - INSTALLATION

1. Disassemble the door's locking system or leave it inactive and
open.
2. Measure the door, and at exactly half its height mark the
reference points on the upper crossbeam and on the ceiling to
facilitate positioning of the guide section bar. It's recommend
install the motor in the door's centre, no more than 100
mm displaced from the door's centre. For a spring operated
and counter-weighted garage doors verify that the distance
between the guide and the door not less than 20 mm.
3. Fasten the bracket E to the upper crossbeam of the door using
plugs G suitable for the type of wall (ø minimum 8 mm).
4. Affix section A to the bracket using the 6x80 round-head
screw F and the self-locking nut provided.
5. Attach the two fixing supports H to section A, positioning
them approx. 1 m from the bracket E
6. Attach bracket I, positioning it close to the motor (approx. 5
cm)
7. Following the reference points previously traced out on the
ceiling, identify the fixing points for the supports H and the
bracket I; drill out the holes and using rawplugs suited to the
ceiling type (minimum diameter 8 mm), fix the automation
device.
8. Use the special drilled bars Q should it be necessary to adjust
the height of the automation device. Assemble the bars as
shown in the following figure, positioning them near the
motor head.
m
PLEASE NOTE: Respect the measurement given in Use
Limits in page 17.
- 19 -