Installation manual
Description
Sensus PulseRF is a radio pulse transponder to be
connected to a pulse output of a meter. It can be connected
with C&I water meters, as well as any other meters with
pulse output such as water, electricity, gas and thermal
energy meters.
Equipment
1. Radio transponder Sensus PulseRF
2. Wall holder
85 mm hole center distance
Required tools
The module can be configured using SensusRF radio with
SIRT and a configuration software such as SensusREAD.
It can be activated automatically after 10 pulses or via
radio.
Pulse interface
The Sensus PulseRF has a 4 wire input enabling the
following functions
• Pulse input (+) (white)
• Cable cut (green)*
• Direction (yellow)*
• Ground (-) (brown)
* Depending on the connected pulse device
Open inputs or unused wires should be isolated
Connection diagram & configuration
Sensus PulseRF - HRI-A3/HRI-B3
Settings:
Cable cut
(green)
Direction ON
Cable Cut OFF
Direction
Direction
(yellow)
(yellow)
Pulses (+)
Pulses (+)
(white)
(white)
Ground (-)
Ground (-)
(brown)
(brown)
www.sensus.com
info.gb@xyleminc.com
Pulse input compatibility
Pulses should be voltage free
Min. pulse length
32 ms (closed)
Min. pulse pause
60 ms (open)
Max. pulse frequency
9 Hz
Detection for closed
(0 - 0.7) V
Detection for open
(2.0 - 2.5) V
Max. cable capacity
10 nF
Max. bouncing time (Reed) 2.5 ms
Internal pull up resistance
10 kOhm
Internal pull up voltage
2.5 V
For the SensusRF radio module choose a position which
affects the radio signal as little as possible. Metal, soil
and water (e.g. power supply line or a water pipe) have
a negative impact on the radio transmission. The effect
of plastic is lower than concrete or wood. Try to avoid a
position close to these materials. In pits the transponder
must be mounted above the water line and at a minimum
distance of 200 mm to metal lid covers. Transponders
should not be closer together than 80 cm. Test the best
position before the final installation.
Radio range
The typical distance between transponder and read-out
device is 500m@868MHz (350m@433MHz) in line of
sight. Poor installation places, obstacles in the radio line-
of-sight and other influences like electrical interference or
metal devices can reduce the radio range or even make
radio reads impossible. From buildings to outside a typical
range is 100 to 200 metres, while in an extreme case the
reading range in a pit might be less than 20 metres.
Installation of the wall holder
The wall plate is surface mounted using two
screws. Leave sufficient slack cable and space so
that the transponder can be replaced in the future.
Do not install the transponder upside down!
Fitting / Removing the transponder
To fit the transponder push the rectangular protrusions on
the back into the mating holes in the wall plate and push
down. To remove the transponder, do it vice versa.
Sensus PulseRF - HRI-Mei B3
Cable cut
(green)
Direction
Direction
(yellow)
(yellow)
Pulses (+)
Pulses (+)
(white)
(white)
Ground (-)
Ground (-)
(brown)
(grey)
Sensus PulseRF
Disposal instructions
This product contains lithium batteries. To
protect the environment it should not be
disposed of in household waste when its
serviceable life is over. Don't destroy or
drill or demolish the module housing!
Disposal can take place through a
Sensus Service Centre. If however you
want to take care of the disposal yourself,
please comply with the local and national
regulations for environmental protection.
Technical data
Technical norms &
see Declaration of Conformity
applied standards
RoHS, WEEE
Frequency
868 MHz (433 MHz)
Transmitter power
25 mW (10mW)
Power supply
Lithium batteries sealed
Typically 15+ years depending on
Battery life time
usage profile
Cable length
2.5 m (max. extension to 15 m)
Protection class
IP 68
Operation
min -20 °C / max +60 °C
temperature
Storage
-20 °C to + 60 °C
temperature
Dimensions
max.: 47 x 120 x 40 mm
Weight
260 g
SensusRF radio protocol
bi-directional
Radio protocol
FlexNet protocol (TFX)
bi-directional
wMBus OMS unidirectional
Sensus PulseRF - Reed RD
Settings:
Cable cut
(green)
Direction ON
Cable Cut OFF
Direction
(yellow)
Pulses (+)
Pulses (+)
(white)
(black)
Ground (-)
Ground (-)
(brown)
(brown)
Sensus PulseRF - open collector
Settings:
Cable cut
(green)
Direction OFF
Cable Cut OFF
Direction
(yellow)
Pulses (+)
(white)
Ground (-)
(brown)
Settings:
Cable cut (optional)
Direction (optional)
Open = forward
Close = backwards

Publicidad

loading

Resumen de contenidos para Xylem Sensus PulseRF

  • Página 1 Pulse interface The wall plate is surface mounted using two Radio protocol FlexNet protocol (TFX) The Sensus PulseRF has a 4 wire input enabling the screws. Leave sufficient slack cable and space so bi-directional following functions that the transponder can be replaced in the future.
  • Página 2 Impuls-Schnittstelle Lagertemperatur -20 °C bis +60 °C bausituationen, wie z. B. Schächten, könnte sich die Re- Der Sensus PulseRF hat 4 Adern. Die Funktionen sind: ichweite auf unter 20 m reduzieren. Abmessungen max.: 47 x 120 x 40 mm • Impulseingang (+) (weiß)
  • Página 3 Sensus RF SIRT et du logiciel de configuration Sensus rendre impossible la lecture radio. La portée typique d'un Read. L' émission radio du module Sensus PulseRF est Température de bâtiment depuis l'extérieur est de 100 m à 200 m, tandis -20 °C à...
  • Página 4 Interfaz de pulsos -20 °C a + 60 °C ser menor a 20 metros. almacenamiento El Sensus PulseRF tiene una entrada de 4 hilos habilitando las siguientes funciones: Dimensiones max.: 47 x 120 x 40 mm Instalación del soporte de pared •...
  • Página 5 Pulsingångskompatibilitet Avyttringsinstruktioner Beskrivning Pulserna ska vara späningsfria Denna produkt innehåller litiumjonbatterier. Sensus PulseRF är en radiopulstransponder som ska Min. pulslängd 32 ms (stängd) För att värna om miljön ska produkten inte anslutas till pulsutgången på en mätare. Den kan anslutas Min.
  • Página 6 20 metriä. SensusRF-radioprotokolla Pulssiliittymä kaksisuuntainen Seinäpidikkeen asennus Sensus PulseRF:ssä on 4-johtiminen tulo, joka mahdollistaa Radioprotokolla FlexNet-protokolla (TFX) Seinälevy kiinnitetään seinän pintaan kahdella kaksisuuntainen seuraavat toiminnot ruuvilla. Jätä riittävästi löysää kaapelia ja tilaa, wMBus OMS yksisuuntainen •...

Este manual también es adecuado para:

Ms 2800