Maintenance; General Maintenance; Brush Replacement - RIDGID R2611 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

WARNING:
When servicing use only identical RIDGID
replacement parts. Use of any other parts may
create a hazard or cause product damage.
WARNING:
Always wear eye protection marked to comply with
ANSI Z87.1. Failure to do so could result in objects
being thrown into your eyes resulting in possible
serious injury.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastic which may
result in serious personal injury.
Electric tools used on fiberglass material, wallboard, spack-
ling compounds, or plaster are subject to accelerated wear
and possible premature failure because the fiberglass chips
and grindings are highly abrasive to bearings, brushes, com-
mutators, etc. Consequently, we do not recommended using
this tool for extended work on these types of materials. How-
ever, if you do work with any of these materials, it is extremely
important to clean the tool using compressed air.
NOTE: FIGURES (ILLUSTRATIONS) START ON PAGE 13 AFTER
FRENCH AND SPANISH LANGUAGE SECTIONS.
LUbRICATION
All of the bearings in this tool are lubricated with a sufficient
amount of high grade lubricant for the life of the unit under
normal operating conditions. Therefore, no further lubrica-
tion is required.

bRUSH REPLACEMENT

See Figure 11, page 14.
 Unplug the sander.
WARNING:
Failure to unplug the tool could result in accidental
starting causing possible serious injury.
 Remove screws (7) from top cover of sander.
 Remove top cover.
 Disconnect lead terminals from brush tubes.
 Remove brush assemblies (2).
 Check for wear. Replace both brush assemblies when
either has less than 1/4 in. length of carbon remaining.
Do not replace one side without replacing the other.
 Reassemble using new brush assemblies. Make sure
curvature of brush matches curvature of motor and that
brush moves freely in brush tube.
 Reassemble by reversing the steps listed above.
 Tighten all screws securely. Do not over tighten.