Descargar Imprimir esta página

Maintenance & Cleaning; Technical Characteristics - Mestra R-080001 Manual De Instrucciones

Microbomba de vacío

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English
The R-080001 is a micro vacuum pump
specially designed for use with MESTRA R-
060220 and R-060230 blenders. To ensure
optimum
performance,
instructions:
Set up the micro-pump on a flat surface well
away from sources of heat and moisture.
The unit has 4 rubber bases (A) to ensure
firm attachment.
Connect the vacuum tube (B) to the
connection point on the blender lid.
Plug the unit into a 230 V, 50/60 Hz earthed
power socket.
Fill the blender body with the materials to be
blended, position the lid and ensure that it is
properly sealed (i.e. that the rubber seal on
the blender lid fits tightly).
Activate the main switch (C). The micro-
pump will start up. After a few seconds the
vacuum inside will ensure that the blender lid
is tightly fixed to the body. Use reasonable
force to ensure that the lid cannot be
removed.
Start blending. After blending, turn off the
micro-pump
at
disconnect the outlet tube (B) from the
blender to release the vacuum, remove the
blender lid and use the mix.
Clean the blender.
MAINTENANCE & CLEANING
To ensure long, reliable service, we recommend
the following:
• After each operation, clean away any plaster
and other materials which may have dropped
accidentally onto the micro-pump housing
before they dry.
4
read
the
following
the
main
switch
GB
• Clean the outside of the unit regularly with a
cloth moistened in soapy water. Always
unplug the unit before cleaning it.
• To prevent the pump body against damage, a
filter has been fitted to the outlet tube. Check
this filter regularly through the viewing port.
When it is dirty, replace it with an original
MESTRA filter.
PRECAUTIONS
♦ Ensure that the mains power voltage is
correct (230 V, 50/60 Hz earthed).
♦ Do not use the unit in very wet areas or
close to inflammable materials (alcohol,
solvents, etc.).
♦ Do
not
personnel to handle the unit.
♦ Do not pull, twist or bend the power cable
excessively.
♦ Disconnect the unit from the mains before
cleaning it.
♦ Do not submerge the unit in any liquid
when cleaning it.
♦ Do not use the suction in the outlet tube for
suctioning pipes or other objects.
(D),
♦ Do not place the outlet tube against your
body while the pump is running.

TECHNICAL CHARACTERISTICS

Power supply:
Consumption:
Vacuum:
Dimensions:
Weight:
allow
children
or
230 V, 50/60 Hz
0.72 A
550-600 mm/Hg
150 x 120 x 100 mm
1.9 kg
unskilled

Publicidad

loading