Carbon Monoxide toxicosis prevention
●This product must exhaust the waste gas to the outdoor area during working, so the flue duct
must be connected to the joint on the top of the water heater to exhaust the waste gas out to the
outdoor area, keep the air fresh indoor and avoid incomplete combustion. Otherwise, it will
cause danger or even death.
●Too low or too high gas pressure leads to abnormal combustion. At that moment, stop using the
water heater and get in contact with a service engineer.
●Dust and accelerated carbon would block the heat exchanger due to long time use, and affect
the combustion performance, causing the Carbon monoxide to increase. Therfore, contact a
qualified person to clean and clear the dust and accelerated carbon every half year to ensure the
combustion product discharges smoothly.
●The heater must be installed vertically, if inclined it will make the flame touch the heat
exchanger and cause the monoxide to increase.
■
Don't drink the heater water
The water in the heater is not suitable for drinking.
6.Handle with abnormal conditions
If there is abnormal burning (flame light-back, flame lift, yellow tip or black smoke, etc), smell or
noise,or other emergent situations, keep calm and shut off the gas supply valve and power
switch, and contact the service facility or gas dealers for repair or adjustment.
■
Scald prevention
●When using the heater discontinuously, be careful not to be scalded by the over high
temperature hot water at the start and stop times.
●During use and immediately after, do not touch any places especially the surround of the flame
Check window or the front cover except for the knob and control panel in order to avoid scalding.
27