GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionaly competent personnel only. Read the instructions carefully before
beginning to install the product. Packaging materials (plastics, polystyrene, etc) must not be allowed to litter the environ-
ment and must be kept out of the reach of children for whom they may be a source of danger. Before beginning the installation
check that the product is in perfect condition. For repairs or replacements of products only original spare parts must be used.
Periodically check for correct operation of the manual release mechanism.
1. INSTALLATION
Installation of the SPRINTBAT battery kit allows the automation to continue operating even when the power supply fails.
charge the batteries.
2. TECHNICAL DATA
Description
Power supply
F2 fuse
Temperature
3. ADJUSTMENTS
DIP1
Selecting the battery kit operating mode.
DIP2
Selecting the continuous operating mode.
kit control board.
All rights reserved.
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any responsibility
for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
SPRINTBAT
12 V 1.2 Ah
F5A
min -10 °C max +50 °C
Description
OFF
Anti-panic mode.
With the mains power supply off,
the automation will carry out an
opening operation at low speed.
When the door is open, the power
supply is disconnected from the
control panel.
Continuous operating.
The battery kit ensures correct
functioning of the door until maxi-
mum battery efficiency is reached.
When the batteries are flat, the
automation will carry out a last clo-
sing operation at low speed. Once
the operation has been comple-
ted, the batteries are disconnected
and the control panel remains de-
energised.
3
ON
Continuous mode.
With the mains power supply off,
the battery kit will guarantee con-
tinuous operating.
Energy saving.
If the door remains closed for more
than 2 minutes the battery kit is
automatically disconnected.
To return to normal operating, an
impulsed KEY command must be
given.