Vision SIMATIC VS130-2 Instrucciones De Montaje página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Wiring Components
Connect the processing unit with the other components using the connectors on the front
panel. The pinning of the connectors is described in Appendix 8.5.
Attention
!
Do not connect or disconnect cables when the power supply is on.
Apart from the Ethernet cable, the cables are supplied with the product (See Appendix 8.1).
Warning
!
Grounding the VS130-2/VS 130-2vcr cancels the ungrounded installation of the power unit
used to operate the VS130-2/VS 130-2vcr.
IN DC 24V
LAMP
Connector
Connector
Type
Label
Functional earth
-
Screw terminal
Power supply
IN 24 V DC
Circular connector M12
Lighting Unit
LAMP
Circular connector M12
Sensor head
SENSOR
HD D-sub *
(shielded cable)
I/O
DI/DO
D-sub
PROFIBUS DP
DP
D-sub
Ethernet
Ethernet
RJ45
*
The supplied ferrite ring must be fixed to the sensor cable (approx. 50 mm from connector
to processing unit).
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr - Installation Instructions
A5E00475766-01
DP
ETHERNET
Number
Cable
Type
of pins
Cross
Section
-
-
-
2
4
0.56 mm
Pin
2
4
0.23 mm
Socket
2
26
0.09 mm
Socket
2
15
0.14 mm
Socket
9
-
Socket
8
-
Socket
Step
Activity
1
Read the guidelines on preventing electrical interference (refer to the manual, Section 3.3).
2
Connect the processing unit to the sensor head and the lighting unit with the cables.
3
If you do not evaluate the result bits READ, MATCH, N_OK over PROFIBUS DP: Connect
the digital outputs READ, MATCH, N_OK as described below ("DI/DO" I/O interface).
4
Connect the trigger signal via the TRG digital input.
5
If you intend to control the SIMATIC VS130-2/VS 130-2vcr with a PLC via the I/O interface
"DI/DO", connect the other digital inputs and outputs as described below (DI/DO interface).
6
Connect functional ground of the processing unit to chassis ground
(Diameter of the ring: (M5, cable cross section 1.5 mm
7
Connect the processing unit to the 24 V power supply (2 A).
8
Connect the PC/PG to the processing unit via Ethernet.
If you want to use this connection as a direct connection, please note that a crossover cable
is necessary.
Note
The DC load power supply must meet the following requirements:
Only low voltage less than or equal to 24 V DC safely isolated from the power
supply network must be used for the load current supply. Safe isolation can be
implemented, for example, by adhering to the specifications in VDE 0100-410 /
HD 384-4-41 S2 / IEC 60364-4-41 (functional low voltage with safe isolation) or
VDE 0805 / EN 60950 / IEC 60950
(as safety extra-low voltage SELV) or VDE 0106 Part 101.
Note
The supply chassis of the I/O and CPU must be connected to the supply chassis
of the processing unit.
2
).
3

Publicidad

Tabla de contenido
loading

Productos relacionados para Vision SIMATIC VS130-2

Este manual también es adecuado para:

Simatic vs130-2vcr

Tabla de contenido