Technical specifications
Ambient, no heat - UF600 (IP54)
1
Type for indoor
Type for
installation
outdoor
installation
UF601 Indoor
UF601 Outdoor 2x4
UF602 Indoor
UF602 Outdoor 2x7,5
UF603 Indoor
UF603 Outdoor 2x11
UF604 Indoor
UF604 Outdoor 2x15
UF605 Indoor
UF605 Outdoor 2x18,5
*) Depends on the design of the floor channel.
Dimensioning
3 m
3 m
UF601
4 m
5 m
6 m
Other door sizes on request. For larger openings, two pillars are required. Please contact Frico.
12
Output
Air
velocity*
[kW]
[m/s]
30
35
38
38
40
Door width [m]
4 m
5 m
6 m
UF601
UF601
UF601
UF602
UF602
UF602
UF603
UF603
UF604
UF600
Voltage
Amperage
[V]
[A]
400V3~
2x7,1
400V3~
2x13,7
400V3~
2x22
400V3~
2x28,5
400V3~
2x33,7
7 m
8 m
UF604
UF605
UF605
Dimensions
Diameter
floor channel
fans
[mm]
[mm]
600x600
500
750x750
630
750x750
630
750x750
630
750x750
630
10 m
UF605
Diameter
silencer
[mm]
750
900
900
900
900