adjusted by the A key or D key and LED displays OP. Repress the P key 2 seconds and the digital screen shows
CL to access the setting of the bottom limit.
1.2 - The position of the bottom limit is also adjusted by the A key or D key and LED displays CL. Once the position
is approved, press the P key 2S and the system quit from the setting of the limit position with the 2 seconds' flash.
Then the door will automatically move from the closing situation (LED displays CL) to the opening situation (the
digital screens show OP). Once the automatic learning comes to end, the opener returns to the stand-by situation
--
and LED displays (
)
P2 - The setting of the power
2.1 - Press and remain on the P key 4 seconds and LED displays P1. Access P2 by pressing the A key. Then press
the P key for 2 seconds and LED displays the current power-grade. To set the reverse power press the A key or D
key. There are 9 grades of the power from F1(min.) to F9 (max).
Once the grade of power is approved, press the P key for 2 seconds and the system quits from the setting of the
--
reverse power. Finally, the system Returns to the stand-by situation (
).
2.2 - The original setting of power-grade: F2
P3 - The setting of the photocell
3.1 - The orginal setting: photocell is unworkable.
3.2 - Press and remain the P key 4 seconds. At the same time, LED displays P1. Access P3 by pressing the A key.
Then press the P key for 2 seconds and LED displays the current status H1 (photocell is workable) or H0
(photocell is unworkable). Press A or D key to select the desired function. Press the P key for 2 seconds and the
--
system quits from the setting of the photocells, returning to the stand-by situation (
).
Diagnosis through courtesy lamp
When the function of the photocell is effected for touching an obstacle, the lamp will flash twice. Then door will go
upward.
When the door reverses direction by effort or obstacle lamp flashes 3 times.
P4 - The setting of the automatic closing time
4.1 - Press and remain on the P key 4 seconds and LED displays P1. Access P4 by pressing the A key. Then press
the P key for 2 seconds and LED displays the current status. The time of automatic closing can be adjusted from
10 seconds to 90 seconds by pressing the A key or D key.
Once the time of the automatic closing is approved, press the P key for 2 seconds and the system quits from the
--
setting of the automatic closing, returning to the stand-by situation (
).
P5 - The setting of the model of the automatic closing
5.1 - Press and remain the P key till LED displays P1 and access to P5 by pressing A key. Then press the P key to
display the current situation. Press A key to access B1 or D to access B0. Finally, press P key to confirm the
--
choice. Then back the stand-by situation (
).
B0: The automatic-closing does not work. The transmitter can stop the opening door. The stopped door will go
downward (close). The closing door will go reversely.
The mode sequence: opening - stop- closing- openning.
B1: The automatic-closing will work at the any position after the set time. For the opening door, the transmitter can
not work. After pressing the transmitter, the fully opened door will close. The closing door will go reversely after
pressing the transmitter.