Wiring Requirements - Bell'O 36II100GRG Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation - Built In Construction
Operation
BUILT IN TO A WALL INSTRUCTIONS
This fireplace is a zero clearance design. No combustibles can be placed on the top surface of the fireplace.
Combustibles may be installed to the edge of the unit. Insulation and vapor barrier should be placed a minimum of 2 in. from the unit.
Build the framing according to the specifications shown in the below table & figure 1.
Model
A
36II100GRG
32.8"
47II100GRG
43.3"

WIRING REQUIREMENTS

Use appropriate wire to meet local and national electrical codes for rated power consumption. All wire gauges should be 12 gauge solid
wires with a dedicated 15 amp breaker for 120 volts.
A1135
B
C
D
18.6"
3.9"
36"
18.6"
3.9"
46.2"
E
F
G
19.7"
4.5"
31.8"
19.7"
4.5"
42.3"
Fig. 1
14
H
I
J
18"
3.5"
37.2"
18"
3.5"
47.5"
www.tsicustomerservice.com
K
L
26.3"
26.3"
33.6"
33.6"

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

47ii100grg

Tabla de contenido