LOW BATTERY

A red LED at the centre of the keypad starts to
flash
RED
when the battery needs replacing.
Also, at each mode change of the
, a low battery tone will be heard.
DigAlert 36x
Once the low battery LED is on,
DigAlert 36x
will keep on working to its specification for a
couple of hours, but
you are advised to
replace the battery as soon as possible
INSTALLING or REPLACING THE
BATTERY
Remove the three hatch cover screws as
shown below. Unclip the battery and replace
it with a 9V alkaline battery. Make the change
within one minute if you want to retain your
memory contents.
It is very important to ensure that the unit
is off when replacing a battery (No LED lit).
Disconnect from the line and press Monitor
m
button to extinguish the Green (Mode) LED.
If you do not do this, when the new battery
is fitted, the test-telephone may not restart
correctly.
To cure it, disconnect the battery for at least 2
minutes and short the terminals together for a
few seconds (when battery not fitted).
Replace the hatch cover ensuring that the line
cord is correctly routed.
Tighten the screws firmly but do not use
excessive force.
Red / Ring / -Ve
Green
/ Earth
Black / Tip / +Ve
Care and repair
Field repair
Field repairs are limited to replacing line cords
(with approved types), replacing belt clips,
and replacing batteries.
repair beyond this at field level is liable to
damage the instrument and will invalidate the
.
manufacturers warranty.
Line-cord changing
Remove the three hatch cover screws.
Replace the cord by loosening the terminal
screws. Connect a new, standard cord as per
the diagram. Tighten the screws firmly but do
not use excessive force.
battery cover locates properly before
securing it with the 3 screws.
Line-cord storage
Wrap the line cord loosely around the handle
or preferably make a few loops and pass them
through the belt clip.
Impact
is highly impact resistant. Even
DigAlert 36x
if dropped from a great height onto concrete
should survive without
DigAlert 36x
permanent damage. In the event that the
gasket seal should bulge out on impact it is
usually possible to gently ease it back into
position with a blunt tool. Do not attempt to
open the case to make a repair nor should any
force be used or the gasket may split. If a
simple local fix is not possible it should be
returned for repair.
Do not open the case.
As a result of impact the surface may be
scuffed or gouged.
Small scuffs may be
removed with fine grit abrasive paper. Any
sharp burrs resulting from impact may be cut
off with a sharp knife. Do not cut into the body
or this will break the water sealing.
Please note that the waterproof seal integrity
can be damaged by a high impact. If in doubt,
please have your unit checked. Use of the
unit while the seals are damaged may
invalidate the warranty.
Warranty
Warranty covers all defects of manufacture
and materials.
Tempo Europe Ltd. agrees to remedy
warranty defects free of charge provided that:
Attempting any
the product is returned pre-paid to the
supplier, it is adequately packed and labelled,
all parts are returned and warranty seals (if
fitted) are not broken.
Warranty does not cover: normal wear and
tear, accidental damage, misuse, abuse or
neglect and is voided by any unapproved
modification.
Make sure the
Tempo Europe Ltd.
Maesglas Industrial Estate,
(
4
š
ü
www.tempo.textron.com
D360&361 User Guide part n° 1201-03-2372 issue 3 08/02, Sheet 1.
Unit 3,
Newport,
NP20 2NN
U.K.
+44 (0) 1633-223 552
+44 (0) 1633-223 948
Contact@cve.co.uk
Hands-Free Test Telephone
DigAlert 360
ADSL compatible
DigAlert 361
USER GUIDE
r
a
n
g
e