Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

FOR USE WITH RANGEMASTER HOODS AND ECLIPSE DOWNDRAFT VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the duct run and number of
elbows and transitions needed are kept to a minimum.
Please note - when using blower with the Broan Eclipse
Downdraft: The downdraft has a 3¼" x 10" discharge.
Transitions are available to connect it to the 10" round inlet
on this exterior-mounted blower.
MODEL 331H or 332H
EXTERIOR BLOWER
SOFFIT
WALL HOOD
CANOPY
(island canopy
available)
DUCT
OPENING
COVER PLATE
24" or 27"
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 3
10" ROUND
DUCT
SOFFIT
WALL HOOD
CANOPY
(island canopy
available)
ROUGH-IN
18"
PLATE
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
MODELS 331H & 332H
EXTERIOR MOUNTED BLOWER
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum for Model 332H or 3 AMPS minimum
for Model 331H.
Important-when using Model 332H with the Broan Eclipse
Downdraft Models 2830-A or 2836-A: Purchase a
#97011927 Speed Control Kit from your Broan distributor
to replace the speed control in your downdraft.
SPECIFICATIONS
MODEL VOLTS
331H
332H
2. Where possible, blower should be centered between wall
studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be running
through the wall.
4. Be sure that there is enough space for any transitions that may
be needed between the blower and the connecting ductwork.
5. For best performance, locate transitions nearest to ventilator
(i.e. downdraft).
NOTE: Horizontal discharge requires relocation of the duct open-
ing cover plate. See hood manual for instructions.
10" ROUND ELBOW
10" ROUND DUCT
MODEL
or 332H
EXTERIOR
BLOWER
DUCT
ROUGH-IN
18"
OPENING
COVER PLATE
24" or 27"
AMPS
120
2.4
120
5.7
SOFFIT
WALL HOOD
CANOPY
(island canopy
331H
available)
18"
PLATE
24" or 27"
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
Page Lm
Page 1
CFM
DUCT SIZE
600
10 " DIA.
900
10" DIA.
10" ROUND DUCT
DUCT
OPENING
COVER
PLATE
MODEL
331H
or 332H
EXTERIOR
BLOWER
ROUGH-IN
PLATE

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan-NuTone 331H

  • Página 1 Page Lm Page 1 MODELS 331H & 332H EXTERIOR MOUNTED BLOWER FOR USE WITH RANGEMASTER HOODS AND ECLIPSE DOWNDRAFT VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING CAUTION 1. For general ventilating use only. Do not use to exhaust TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: hazardous or explosive material and vapors.
  • Página 2 Page Lm Page 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1. Locate the blower on the rear slope of the roof. 1. Choose a position on the outside wall. Make sure Place it in a location to minimize duct run. The that no wall studs, pipes or wires run through the location should be free of obstacles (T.V.
  • Página 3 Page 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove roofing nails from the upper 2/3 of the 1. Place a large bead of caulk on the back side of the shingles around the cutout area and carefully lift the housing along the outer edge.
  • Página 4: Service Parts

    NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) 99043017B Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)
  • Página 5: Planification De La Pose

    Page Lm Page 5 MODÈLES 331H & 332H VENTILATEUR À MONTAGE EXTÉRIEUR POUR UTILISATION AVEC LES HOTTES RANGEMASTER ET LES VENTILATEURS ENCASTRÉS ECLIPSE VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER ATTENTION AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS DE MANIÈRE À RÉ- 1.
  • Página 6 Page Lm Page 6 PRÉPARATION DE PRÉPARATION DE L’EMPLACEMENT DE POSE L’EMPLACEMENT DE POSE POSES SUR LES TOITS POSE SUR UN MUR 1. Choisissez un emplacement sur le mur extérieur. Assurez- 1. Choisissez un emplacement pour le ventilateur sur la pente vous qu’aucun poteau mural, tuyau ou câble ne passe au arrière du toit.
  • Página 7: Installation Du Ventilateur

    Page Lm Page 7 POSE DU VENTILATEUR INSTALLATION DU VENTILATEUR POSE DU VENTILATEUR POSE SUR UN MUR 1. Retirez les premiers deux tiers des clous à toiture des 1. Appliquez une large bande de produit à calfeutrer à l’arrière bardeaux se trouvant autour de la surface de découpe puis du boîtier, le long du rebord extérieur.
  • Página 8: Pièces De Rechange

    Veuillez commander les pièces par N° PIÈCE - et non par N° présenter une preuve de la date d’achat original. REPÈRE. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1- 800-543-8687) Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga,...
  • Página 9: Especificaciones

    6 amperios para el Modelo 332H o Cuando no sea posible bloquear los medios de desconexión del 3 amperios para el Modelo 331H. servicio, fije firmemente en un lugar prominente del panel de servicio Importante: cuando use el Modelo 332H con los tiros descendentes un dispositivo de advertencia , como por ejemplo una etiqueta.
  • Página 10: Instalación

    Página 10 Page Lm PREPARE EL LUGAR DE LA PREPARE EL LUGAR DE LA INSTALACIÓN INSTALACIÓN INSTALACIONES EN EL TECHO INSTALACIONES EN LA PARED 1. Ubique el ventilador en la pendiente posterior del techo. Colóquelo 1. Seleccione un lugar en la pared exterior. Asegúrese de que no haya en un área en la cual minimice la longitud del tramo de conductos.
  • Página 11: Instale El Ventilador

    Página 11 Page Lm INSTALE EL VENTILADOR INSTALE EL VENTILADOR INSTALACIONES EN EL TECHO INSTALACIONES EN LA PARED 1. Coloque un reborde grande de material de calafateo en el lado 1. Quite los clavos del techo de las 2/3 partes de las tejas superiores posterior de la cubierta, a lo largo del borde externo.
  • Página 12 En el momento de solicitar servicio cubierto por la garantía, usted debe de presentar evidencia de la fecha original de compra. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1- 800-543-8687) Broan-NuTone Canada, Inc., 1140 Tristar Drive,...

Este manual también es adecuado para:

332h

Tabla de contenido