Terminal Connections - VDS POWER 1R0 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
1. APLICATIONS
Equipment designed for industrial aplications like speed doors, industrial sectional doors or heavy sliding doors.
Supports:
- DMT: Magnetic selector card /safety int. / opening.
- SRT BAND: WIRELESSBAND system receiver card for resistive / optical safety edge.
- SRT: Radio card receiver for 433 or 868 Mhz radio transmitters.
2. OPERATING INSTRUCTIONS
- The control unit can be activated by Test CI, P.ABRIR(26-28) or via the radio card. Manoeuvres can be finalised via the following: limit switch activation, end of
working time or by encoder .
- With option 3 ON, if the OPEN button or transmitter is pushed while the door is opening, it stops and does not close the door.
- Pressing the STOP button stops the door. It is necessary to push OPEN or CLOSE buttons to reactivate the operation.
- With option 3 ON, If the OPEN button or transmitter is pushed while the door is closing, then the door will open.
- The garage light contact is activated when the door is opening & deactivated after 2 seconds.
3. CONNECTIONS
I1. CIERRE AUTOMATICO
I2. INVERSION AL ABRIR
I3. ALTERNATIVO / ABRIR
I4. HOMBRE PRESENTE
I5. ENCODER DIGITAL
I6. CTOS PUERTA ABIERTOS
I7. FOTO1 / BANDA
I8. TEST FOTOCELULA
I9. PREDESTELLO
I10. TIEMPOS DIGITALES
OPEN
CONTACTOR
CLOSE
CONTACTOR
BRAKE
STOPPER

3.3 TERMINAL CONNECTIONS

Power free
(contact) or
220V,
depending
on model.
SAFETY EDGE
(OPTION 7 ON)
21 22
21 22
8K2 Ohm
N.O
N.C
Safety Edge
Safety Edge
POWER 1R0
EURO 380 M1
RADIO CARD
POWER SUPPLY
WORKING
AUTOMATIC
REVERSE
TIME
CLOSING
TIME
TIME
PROG. BUTTON
LOOP
DETECTOR
12 V.AC.
Rs484
VDD
A
B
+
-
OPEN
CLOSE
YES
NO
FLASHING
DOOR OPENED
DOOR CLOSED
OPEN
TEST
SAFETY
CLOSE
FLASHING
DOOR
DOOR
CLOSE
EDGE
STOP
FOTO
SAFETY
OPENED
CLOSED
CLOSE
FLASH
BRAKE
220V
11 12
5 6
220V
BRAKE
OPEN
SAFETY
(OPTION 7 OFF)
21 22
CSEG.
OPEN
3.1 POWER SUPPLY & MOTOR CONNECTIONS
TRIPHASE
POWER SUPPLY
S
N
R
T
N
R
S
T
380V TRIPHASE
MOTOR
U V W
M
3
3.2 LOOP DETECTOR
OPEN
OPENED
CLOSED
DOOR
DOOR
13 14
15 16
OPEN
CLOSE
CLOSE
PUSH
SAFETY
BUTTONS
25 26 27 28
23 24
CSEG.
STOP CLOSE OPEN
CLOSE
220V TRIPHASE
POWER SUPPLY
N
R
S
T
N
R
S
T
220V TRIPHASE
MOTOR
U V W
M
3
WITHOUT
LOOP
DETECTOR
LIMIT
AUTOTEST
SWITCHES
17 18 19
OPEN CLOSE
LIMIT SWITCHES
ACCESSORIES
DIGITAL ENCODER
POWER SUPPLY
29 30
12V
MONOPHASE
POWER SUPPLY
N
R
S
T
N
L
220V MONOPHASE
MOTOR
U V W
M
1
WITH
LOOP
DETECTOR
20
MUTE
31 32
33 34
A
B
+ -
VDD
RS485
1 - 4

Publicidad