Place oven where it will be well lighted. For proper baking
and cooking results, oven must be level. Use a spirit level
on center oven rack to level. THIS ELECTRIC OVEN IS
APPROVED FOR INSTALLATION IN COMBUSTIBLE
CABINETRY. SEE INSTALLATION DIAGRAM FOR THE
OVEN.
lrqpfab tfofkd
Your local utility company will tell you whether the present
electric service to your home is adequate. It may be
necessary to increase the size of the wiring to the house
and service switch to take care of the electrical load
demanded by the oven and/or top section. The wattage
(K.W. rating) load for the oven is specified on the name
plate on the unit.
elrpb tfofkd
Most local building regulations and codes require that all
electrical wiring be done by licensed electricians. All
wiring should conform to Local or National Electrical
Codes. This oven requires a single phase three wire
120/240 or a 120/208 volt, 60 Hz. AC circuit. Wiring codes
require that a separate circuit be run from the main
entrance panel to the oven and that it be equipped with
separate disconnect switch and fuses, either in the main
entrance panel or in a separate switch and fuse box.
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCI) outlet or breaker is in use.
o^kdb `lkkb`qflkp
The flexible armored conduit supplied with the oven must
be connected to an approved electrical junction box by
means of an approved conduit to box connector. THE
FRAME OF THE OVEN IS GROUNDED TO NEUTRAL
ONLY WHEN THE WHITE AND BARE WIRES AT THE
END OF OVEN CONDUIT ARE JOINED TOGETHER.
Connect the white and bare wire at the end of the oven
conduit to the neutral (white) wire of the branch circuit. If
used on new branch-circuit installations (1996 NEC),
mobile homes, recreational vehicles, or in an area where
local codes prohibit grounding through the neutral
conductor, untwist or disconnect the bare wire and
connect the bare wire to ground in accordance with local
code. Connect the white wire to the branch circuit. The
red and black wires must be connected to the remaining
two conductors of the branch circuit. Connect all wires to
the branch circuit with approved connectors. Use copper
or aluminum wire. If aluminum wire is used, use
connectors recognized for joining aluminum to copper.
Be sure OVEN is DISCONNECTED from POWER
SUPPLY before examining any of the electrical
equipment.
APPROVED CONNECTOR
BLACK
WHITE
L1
NEUTRAL
o^kdb dolrkaba qeolrde kbrqo^i `lkar`qlo
PJtfob fkpq^ii^qflk
APPROVED CONNECTOR
BLACK
WHITE
L1
NEUTRAL
tfofkd jbqela fc `lab albp klq mbojfq dolrkafkd
qeolrde kbrqo^i `lkar`qlo C ^ipl obnrfoba fk jl_fib
eljbpK
QJtfob fkpq^ii^qflk
3
RANGE CONDUIT
RED
BARE
APPROVED BOX
APPROVED
CONNECTION
L2
BRANCH CIRCUIT
(POWER SUPPLY)
RANGE CONDUIT
RED
BARE
APPROVED BOX
APPROVED
CONNECTION
L2
BRANCH CIRCUIT
(POWER SUPPLY)
SEPARATE GROUND