Standard Features
Subsonic Filter
24dB/Octave Variable 20-80 Hz
Fully Regulated PWM Power Supply
All Xtant "A" Series amplifiers feature a Fully Regulated, Pulse Width Modulated
power supply. This supply technology provides high efficiency and consistent output
performance even when battery voltage is less than optimum.
Crossover
A 24dB/Octave low pass filter network with variable 40-120 Hz frequency selection is
included.
Balanced/Floating Input
When enabled, this circuitry helps to eliminate "system noise" associated with
"ground loops". When combined with the input sensitivity adjustment, it allows
the A Series to accept up to 17V of input signal. Balanced must be used for BTL
inputs using the HLA.
Protection Circuitry
Both Thermal and Overcurrent protection are incorporated into the "A" Series
Amplifiers. In the event of a problem, the amplifier will reduce its power to
maintain operation.
Status LEDs
(Located on the top of the amplifiler)
Three LEDs, indicate operational status of all Xtant A Series amplifiers. The red LED
illuminates when the amplifier is "ON", the yellow LED indicates that overcurrent
protection is engaged, the orange LED indicates that the thermal protection circuit
is engaged.

Optional Performance Upgrades

High Level Adapter (HLA)
This adapter allows you to connect a source unit with speaker level outputs to your
Xtant amplifier.
Remote Level Control (RLC)
The RLC or Remote Level Control allows a remote bass control to be adjusted from
the driver's seat.
4
English
English
Frequency Response:
Number of Channels:
Watts per Channel @ 4Ω:
Watts per Channel @ 2Ω:
Recommended Load:
Distortion (THD):
Measured: 20 Hz to 120 Hz at rated power, all channels driven 4Ω
Signal to Noise Ratio:
Measured: A-weighted in 20 kHz noise bandwidth @ 1 volt sensitivity
Damping Factor:
Input Sensitivity:
Input to Line Output Gain:
On-Board Crossover:
Balanced Line:
Power Supply:
Operational Voltage:
Fusing Requirement:
Size (L xW x H):
Subsonic Filter:
Bass Boost:
Warranty:
Xtant A3001 Specifications
20 Hz to 120 Hz +/– 1 dB
≥ 100 @ 100 Hz with 4Ω load
100 mV to 8.5 V RMS Unbalanced
200 mV to 17 V RMS
24 dB/Octave Low Pass
Fully Regulated, PWM
11-5/8" x 9-1/4" x 1-7/8"
295mm x 235mm x 47mm
24 dB/Octave 20-80 Hz
Limited 4 Year Parts and Labor
(See page 8 for details)
1
1 x 150
1 x 300
≥2Ω
≤2%
≥ 100 dB
Balanced
0 dB
On Board
10 to 16 Volts
40 Amp
0-12 dB @ 45 Hz
5