NORMAL OR ANGLE STYLE FAN MOUNTING
1. Insert downrod (A) through canopy (B), canopy cover (X) and yoke
cover (E). (Note: Canopy cover (X) must be turned with the shiny
side toward the motor housing (D). [Fig. 1] Thread wires from motor
housing (D) through downrod (A).
*Helpful Hint: Downrod style mounting is best suited for ceilings 8 ft.
(2.44 m) high or higher. For taller ceilings you may want to use a
longer downrod (not included) than the one provided. Angle style
mounting is best suited for angled or vaulted ceilings. A longer
downrod is sometimes necessary to ensure proper blade clearance.
2. Remove pin (R) and clip (S) from motor housing yoke. Slip
downrod (A) into motor housing yoke, align holes and re-install pin
(R) and clip (S). Tighten downrod (A) set screws and then tighten
nuts. Slide yoke cover (E) down until it rests on top of motor
housing (D). [Fig. 2]
3. Install ball end of downrod (A) into mounting bracket (C)
opening. Align slot in ball with tab in mounting bracket (C). [Fig. 3]
Warning: Failure to align slot in ball with tab may result in
serious injury or death.
WIRING (continued on the following page)
WARNING: To reduce the risk of fire, electrical shock,
or personal injury, wire connectors provided with this fan are
designed to accept only one 12 gauge house wire and two lead
wires from the fan. If your house wire is larger than 12 gauge
or there is more than one house wire to connect to the two fan
lead wires, consult an electrician for the proper size wire
connectors to use.
Important: Be sure wiring box is properly grounded or
that a ground wire (green or bare) is present.
Warning: If house wires are different colors than
referred to in following steps, stop immediately. A professional
electrician is recommended to determine wiring.
1. Choose wiring diagram [Fig. 1A, Fig. 1B or Fig. 1C] that fits
your situation and make appropriate wiring connections as
follows: (Make special note of Step 3 on the following page
while wiring.)
1A. Connect BLACK and BLUE wire from fan to BLACK
wire from ceiling with wire connector (O) provided. Connect
WHITE wire from fan to WHITE wire from ceiling with wire
connector (O) provided. Connect all GROUND (GREEN)
wires together from fan to BARE/GREEN wire from ceiling
with wire connector (O) provided. [Fig. 1A]
1B. If you intend to control the fan light with a separate wall
switch, wire as indicated in the instructions in 1A except
connect BLUE wire from fan to the BLACK supply from the
independent switch. [Fig. 1B]
[See next page for 1C.]
FAN AND LIGHT CONTROLLED BY CHAIN.
Fig. 1A
BLACK (POWER)
WHITE (NEUTRAL)
GROUND
GROUND
FAN CONTROLLED BY CHAIN, LIGHT BY WALL SWITCH.
Fig. 1B
BLACK (POWER)
WHITE (NEUTRAL)
GROUND
GROUND
4
B
A
E
Fig. 1
A
E
Set
Screw
S
R
Fig. 2
C
A
Fig. 3
BLACK
BLUE
WHITE
SWITCHED
LIGHT
POWER
BLACK
WHITE
BLUE
X
D
B