Descargar Imprimir esta página

Fiap Aqua Active Magic Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
FIAP Aqua Active Magic
Electrical connection
The electrical connection has to be done by an authorized professional under the directives of the EVU
and VDE. All installations of the pump have to be done by the VDE 0100 part 702. For all power data
see specification plate. Disconnect all power when working on this device!
Starting up
Attention! Never use the device without filter-basket or filter-sieve and without water running
through it!
The device has a motor with protection category IP X4. The site of the pump must be dry and well
ventilated. The pump should be installed in a closed space; a water drain must be present. The size of
the floor drain depends mainly on the size of the pool, the circulation flow rate but also about the
possibility of possible leaks in the pool water circulating system. The ambient temperature must not
exceed 40 ° C.
If is installed outside always use a protection against rain, which will extend the lifetime of your device.
In a closed room, like a basement, you have to install a drain for the water. In a room with a high
humidity you have to take care for an effective air-circulation to prevent condensation. In a small room,
with little natural air-cooling, an additional aeration and deaeration is necessary to avoid a higher
ambient temperature than +40 °C. Make sure that structure-borne sound or airborne-sound of the
9
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
www.fiap.com

Publicidad

loading

Este manual también es adecuado para:

S57192S45974S57155S57196