5) Maintenance
The TTP programmer does not normally require any type of mainte-
nance as it does not contain parts subject to wear. Only the batter-
ies need to be replaced periodically (or recharged in the case of
rechargeable batteries).

5.1) Replacing the batteries

If you use non-rechargeable batteries, remove the panel on the bot-
tom of the box and replace the batteries, taking care to adhere to the
polarity marked on the bottom of the battery compartment.

5.2) Disposal of the batteries

Discharged batteries are highly polluting and it is therefore compul-
sory to dispose of them in the appropriate disposal containers.

5.3) Recharging the batteries

If you use rechargeable batteries, recharge them by connecting the
battery charger to a power socket and then to the TTP. Leave to
recharge for about 15 hours, then disconnect. If the time for which
the batteries retain their charge decreases significantly, they have
deteriorated and should be replaced.
5.4) Environmental protection measures
This product consists of various types of materials, some of which
can be recycled.

6) Technical specifications

Type
Power supply
Battery life
Operating temperature
Protection class
Dimensions and weight
Nice S.p.A. reserves the right to modify its products at any time it deems necessary.

EC Declaration of conformity

IN ACCORDANCE WITH DIRECTIVE 89/336/EEC
Number: 182/TTP
The undersigned Lauro Buoro, Managing Director, hereby declares that the product:
Manufacturer's name NICE S.p.A.
Address
Via Pezza Alta 13, 31046 Z.I. Rustignè –ODERZO- ITALY
Model
TTP
meets the essential requirements of Directive 89/336/EEC relating to electromagnetic compatibility.
ODERZO, 30-03-2004
Programming unit for control units and motors predisposed for TTBUS connection
Internal: 2 type AA 1.5V batteries, or 2 type AA 1.2V, 2000mAh rechargeable batteries
External: 12V DC, 300 mA battery charger power supply unit
Estimated as approximately 20 operating hours
-20°C + 55°C
IP 20 (only for use in sheltered environments)
155 X 96 X 28,2h / 220g
Date: 30/03/2004
Revision: 0
When the batteries are discharged, the TTP emits a long beep at
intervals of about 10 seconds; on the third beep, the TTP switches
off automatically.
!
Do not attempt to recharge ordinary alkaline batteries. If
you want to power the TTP with the battery charger power
supply unit it is advisable to remove the batteries.
!
Some components may contain polluting substances. Do
not discard this product as ordinary refuse but find out about
the recycling or disposal systems for the product and comply
with the methods prescribed in local regulations.