CHAFFOTEAUX ZONE CONTROL EVO Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
technical adjustments
TABLE OF PARAMETERS
CABLED AND WIRELESS VERSIONS
- Hold "+" down for 5 seconds. The display will alternate between the software version and
modifi cation index.
- Press "OK" to enter the settings menu.
- Press "+" and "-" to scroll through the parameters.
- Press "OK" button to select a parameter.
Par.
CF01
CF11
CF12
WIRELESS VERSION
- Hold "+" down for 5 seconds. The display will alternate between the software version and
modifi cation index.
- Hold "+" down for 5 seconds again to enter the technical parameters menu; parameter "rF01"
will display
- Press "OK" to enter the settings menu.
- Press "+" and "-" to scroll through the parameters.
- Press "OK" button to select a parameter.
Par.
rF01
rF02
rF03
rF04
TABLE OF ERRORS
Error
Err – Ebus
Err – rout
- - -
Err
Description
Room temperature correction (range +/-5°C)
0: Display OFF after 10s
1: Display always on
0: Backlight off
1: Backlight OFF after 5s of inactivity
Description
Detect device (0 - 15)
Associate zone (1 - 6)
Signal level (0 - 4)
Association (0 - 1)
Cause
Zone association error: the
zone associated with the
device is already assigned
Radio communications error:
the room sensor is out of
range of the receiver or aerial
The room sensor is damaged
Solution
Check the installed room sensors. Associ-
ate a diff erent zone
Check the signal strength with parameter
"rF03"
Use an aerial.
Reposition the room sensor.
Repeat the association procedure
Replace it
Default
0°C
1
1
Default
GB - 23

Publicidad

Tabla de contenido
loading

Productos relacionados para CHAFFOTEAUX ZONE CONTROL EVO

Este manual también es adecuado para:

33191173319119

Tabla de contenido