associating the wireless device
OUTDOOR PROBE
• Position the wireless outdoor sensor
near the aerial.
• Check that the aerial is powered up
with its green led on (Fig. 3).
• Open the cover of the outdoors sensor
by undoing the two screws.
• Set the dip switch on the external sen-
sor's pcb to ON (Fig. 4).
• Hold the button on the aerial down for
5 seconds (Fig. 3); the red led will start
fl ashing. The aerial is now ready to re-
ceive the signal
• Press the button on the external sen-
sor's board until red led A turns on for 2
seconds (Fig. 5).
• Press the button again to send the
measured temperature value to the
aerial.
• Wait a few seconds for the association
procedure to terminate.
• If the procedure has terminated suc-
cessfully, the red led on the aerial will
go out.
• The aerial and sensor are now ready
for normal operation.
If the association procedure fails, the
red led on the aerial will stay on. In this
case, repeat the procedure as described
above.
If other devices are already associated,
the red led will remain off even if associ-
ation has failed. Check the external tem-
perature on the system interface.
You can associate more than one aerial
with a given external sensor by repeat-
ing the procedure for each aerial.