Position Of The Probes (Rif. 21) - Specialized Technician; Start, Control, And Adjustment Of The Temperature - Specialized Technician; Loading The Cabinet - Qualified Operator - Arneg Coimbra 2 VCA Serie Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Coimbra 2
VCA-VPA-VCB-SELF-H125
English
The installer must provide the anchoring devices for all the wires in input and output to/
from the cabinet.
Prevent the casing from making contact with the electrical panel to avoid
electrical shocks that can cause injuries or death.
Check that the connections of the various lighting devices (floors, roof,
superstructure) are properly inserted and locked into their respective sockets,
so as to prevent disconnections during cleaning and maintenance operations
that may cause electrical shocks harmful to the operator.
The automatic magneto-thermal switch must be such that it does not open the circuit
on the neutral, without simultaneously opening on the phases and, at any rate, the
distance between the opening of the contacts must be at least 3 mm.

12. Position of the probes (Rif. 21) - specialized technician -

The probes are already assembled in the cabinet and are:
Sout Green air inlet control probe
Sdef Black defrost end thermal switch control probe
Sin
Yellow suction air control probe
Temperature probe: NTC IP67 .
Attach the Sout probe with cable clips cod.04530900;
Attach the Sin probe with probe clip cod.04351103;
Attach the Sdef probe in contact with the aluminium fins with stainless steel spring
cod.02230134 between the 1st and 2nd pipe.
13. Start, control, and adjustment of the temperature
- specialized technician -
The refrigeration temperature is controlled using the mechanical thermometer (Rif. 12)
or with the electronic control device (OPTIONAL) (Rif. 13).
Normally, the controller is programmed in the factory during the testing phase; in case
the programmed setting is changed, refer to the instructions provided by the
manufacturer of the controller.

14.Loading the cabinet - qualified operator -

To stock up the cabinet, certain important rules must be followed:
arrange the goods in an orderly and uniform fashion (Rif. 10).
Arrangement of the goods without empty spots ensure better operation of the
cabinet.
distribute the goods so as not to disturb flow of the refrigerated air (Rif. 10)
The refrigerated cabinet is meant to preserve the temperature of the product
displayed and not to lower it. The food products must be introduced into the
cabinet only if already cooled down to their respective preservation
temperatures.
arrange the goods in an orderly and uniform fashion .
DO NOT introduce products that have been heated..
DO NOT obstruct the refrigerated air entry in an way (merchandise, price
labels, price holders, etc.)
Model H125-150:
DO NOT load the top of the unit with boxes, packages, or other things (Rif. 17).
DO NOT overload the shelves (max load 160 kg/m
34
2
) (Rif. 10).
05060143 00 10/04/2013

Publicidad

Tabla de contenido
loading

Tabla de contenido